Impedance measurement for nondestructive venison pH estimation using touch-type electrodes
Akari Igarashi1, Takayuki Muramoto2
1Graduate School of Arts and Sciences, Iwate University, Morioka, Japan.
Animal Science Journal = Nihon Chikusan Gakkaiho
|January 8, 2025
Summary
Measuring venison
Area of Science:
- Food Science
- Meat Science
- Electrical Engineering
Background:
- Deer capture methods influence venison pH, impacting water-holding capacity (WHC) during heating.
- Accurate WHC assessment is crucial for venison processing and cooking.
- Current methods lack non-destructive ways to differentiate normal- and high-pH venison.
Purpose of the Study:
- To explore the relationship between venison pH and electrical impedance.
- To develop a non-destructive method for estimating venison pH.
Main Methods:
- Investigated the correlation between venison pH and impedance using touch-type electrodes.
- Measured impedance at 10 kHz before storage.
- Correlated impedance with pH after 24 hours of storage and drip loss.
Main Results:
- Found significant negative correlations between pre- and post-storage pH and drip loss (p < 0.05).
- Established a significant negative correlation between pre-storage impedance (10 kHz) and post-storage pH (p < 0.01).
- Developed an equation (y = -0.10x + 10.84) to estimate venison pH non-destructively.
Conclusions:
- Non-destructive estimation of venison pH is possible using impedance measurements.
- Touch-type electrodes at 10 kHz offer a viable method for assessing venison quality.
- This technique can aid in processing and quality control of venison.
Related Concept Videos
pH
The potential of hydrogen (pH) is a measure of the acidity or basicity of a water-based solution determined by the concentration of hydronium ions (H3O+). In one liter of pure water at neutral pH, there are 1×10−7 moles of hydronium ions. However, the extensive range of hydronium ion concentrations present in water-based solutions makes measuring pH in moles cumbersome. Therefore, a pH scale was developed to convert moles of hydronium ions into the negative logarithm of the hydronium ion...
Potentiometry: Overview
Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Potentiometry: Types of Electrodes
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Controlled-Potential Coulometry: Electrolytic Methods
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
The chosen potential ensures...
Amperometry: Overview
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...