Electrochemical study of anti-platelets tirofiban HCl in dosage form using nanomaterials modified sensors: developed

Mohamed Rizk1, Maha Mahmoud Abou El-Alamin1, Ola Abd Elkhalek2

  • 1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Helwan University, P.O.Box 11795, Cairo, Egypt.

BMC Chemistry
|January 9, 2025
PubMed

Insights

A new electrochemical method accurately quantifies tirofiban hydrochloride in pharmaceuticals. This method, using a modified carbon paste electrode, is crucial for treating heart failure and ensures drug quality.

Area of Science:

  • Analytical Chemistry
  • Electrochemistry
  • Materials Science

Background:

  • Tirofiban hydrochloride is vital for inhibiting platelet aggregation, impacting congestive heart failure treatment.
  • Accurate quantification of tirofiban hydrochloride in pharmaceutical formulations is critical due to its role in managing a leading cause of death.
  • Existing quantification methods may lack the sensitivity or efficiency required for pharmaceutical analysis.

Purpose of the Study:

  • To develop and validate a novel electrochemical method for determining tirofiban hydrochloride in pharmaceutical dosage forms.
  • To utilize a modified electrode for enhanced electrochemical detection of tirofiban hydrochloride.
  • To assess the environmental impact and greenness of the developed analytical method.

Main Methods:

  • Development of a carbon paste electrode modified with multi-walled carbon nanotubes (MWCNT).
  • Electrochemical determination of tirofiban hydrochloride using the modified electrode.
  • Characterization of the electrode's morphology via Scanning Electron Microscopy (SEM) and Energy-Dispersive X-ray analysis (EDX).
  • Validation of the method, including linearity, limit of detection, and correlation coefficient assessment.
  • Evaluation of the method's greenness using the eco-scale and Green Analytical Procedure Index (GAPI).

Main Results:

  • A linear electrochemical response for tirofiban hydrochloride was achieved in the range of 27.00-745.00 ng/mL.
  • A high correlation coefficient of 0.9995 indicates excellent linearity.
  • The method demonstrated a low detection limit of 15.50 ng/mL.
  • Morphological analysis confirmed the successful modification of the carbon paste electrode with MWCNTs.
  • The greenness profile of the method was successfully assessed.

Conclusions:

  • The developed electrochemical method provides a sensitive and reliable approach for quantifying tirofiban hydrochloride in pharmaceutical formulations.
  • The MWCNT-modified carbon paste electrode offers enhanced electrochemical performance for tirofiban hydrochloride detection.
  • The method's green characteristics make it an environmentally friendly option for pharmaceutical quality control.