Direct Printing of an Electrochemical Device and Its Interface with Paper for Uric Acid Detection in Human Sweat
Rutuja Kale1, Mayur Krishna Das1, Arun Dodde Gowda1
1Department of Medical Devices, National Institute of Pharmaceutical Education and Research, Guwahati, Assam 781101, India.
Abstract:
Using a laser-scribed (direct printing) technique, we have fabricated an enzymeless, mediatorless, and paper-interfaced electrochemical device (P-LSG) for uric acid detection on a flexible polyimide sheet. Various paper substrates were investigated, and it was found that Whatman filter paper-1 is promising to obtain the best electrochemical signals at the small volume of electrolyte, i.e., 20 μL. Furthermore, the Whatman filter paper-1 was modified with gold nanoparticles (AuNPs) to improve the electrocatalytic activity of the P-LSG device. The fabricated AuNP-modified P-LSG biosensor exhibited excellent electrocatalytic activity for the detection of uric acid over a wide range of 10 to 750 μM, with sensitivity of ∼0.214 μA μM-1 cm-2, and a limit of detection of ∼1.4 μM. The sensor was further validated by using the UHPLC-ESI-MS/MS technique, and the observed percentage recovery was less than 10%. This work opens the window to modified paper substrates with various nanomaterials to improve the sensing parameters. The electrolyte storage capacity and rich chemistry of paper additionally provide an efficient immobilization platform for biorecognition elements to diagnose other metabolites. Furthermore, it has the potential to analyze the volume of small samples (like sweat, tears, urine, etc.) using paper to develop noninvasive wearable biosensors.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Interfacial Electrochemical Methods: Overview
Potentiometry: Membrane Electrodes
Amperometry: Overview
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Instrumentation
