Related Experiment Video
Updated: Jun 16, 2025

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Are we systematically overdosing women? Revisiting standardized contrast protocols for thoracoabdominal CT scans
Judith Becker1, Adrian Huber1, Stefanie Bette1
1Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany.
Objectives:
The purpose of this study was to evaluate whether the iodine contrast in blood and solid organs differs between men and women and to evaluate the effect of BMI, height, weight, and blood volume (BV) on sex-specific contrast in staging CT.
Materials And Methods:
Patients receiving a venous-phase thoracoabdominal Photon-Counting Detector CT (PCD-CT) scan with 100- or 120-mL CM between 08/2021 and 01/2022 were retrospectively included in this single-center study. Image analysis was performed by measuring iodine contrast in the liver, portal vein, spleen, left atrium, left ventricle, pulmonary trunk, ascending and descending aorta on spectral PCD-CT datasets. Univariable and multivariable analyses were performed to assess the impact of sex, age, BMI, height, weight, and BV on the iodine contrast.
Results:
A total of 274 patients were included (mean age 68 years ± 12 SD, 168 men). Iodine contrast in organs and blood attenuation was significantly higher in women when using the same volume of CM. Sex, age, BMI, height, weight, and BV significantly influenced iodine contrast. After adjusting for confounding variables, sex remained a significant factor, with women having higher parenchymal and vascular iodine contrast.
Conclusion:
Standardized or weight-adapted use of CM in venous-phase thoracoabdominal CT scans results in significantly higher contrast in women compared to men. Customizing the CM dose to the patient's BV could result in a similar contrast between sexes. This approach has the potential to reduce the amount of CM, resulting in cost savings, and to decrease the risks associated with CM, particularly for the female sex.
Key Points:
Question This study addresses whether current standardized iodinated contrast media protocols lead to systematically higher iodine enhancement in women than in men during thoracoabdominal CT. Findings Women consistently show greater iodine enhancement in blood and abdominal organs compared to BMI-matched men when receiving identical volumes of contrast media. Clinical relevance Adjusting contrast media dosage based on blood volume in venous-phase CT scans could equalize parenchymal and intravascular iodine enhancement across sexes. This approach may reduce unnecessary contrast exposure in women, lower associated risks, and optimize healthcare resource allocation.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET