Related Experiment Video
Updated: May 12, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Transatlantic Telerobotic Coronary Angiography: A Pre-clinical Feasibility Study
Ryan D Madder1, Stacie VanOosterhout1, Jessica L Parker1
1Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan, USA.
Background:
Patients in many underserved geographies lack access to invasive coronary angiography (ICA).
Objectives:
This preclinical study explored the feasibility of telerobotic ICA between separate continents.
Methods:
Using a novel robotic system, attempts were made to navigate a magnetic guidewire and diagnostic catheter from the aortic arch into a target coronary artery ostium in a fluid-filled cardiac model. The model and robotic system were located in Zürich, Switzerland. The operating physician was either "onsite" in the laboratory in Zürich or "transatlantic," in which the physician remotely controlled the robot from Grand Rapids, Michigan, USA. An onsite control group of 40 manual catheterization cases was made for comparison. The primary endpoint was technical success (catheter engagement into target ostium without conversion to manual). A secondary endpoint was engagement time (time from initial robotic manipulation to engagement in target ostium).
Results:
In 260 consecutive attempts, of which 40 (15.4%) were "onsite" and 220 (84.6%) were "transatlantic," technical success was 97.5% onsite and 100% in the transatlantic group (P = 0.154). Median engagement times were 33.2 seconds (25th, 75th percentile: 24.9, 45.0 seconds) onsite and 26.7 seconds (25th, 75th percentile: 21.7, 35.5 seconds) transatlantic (P = 0.003). Median engagement time was faster for manual cases (17.1 seconds [25th, 75th percentile: 12.2, 23.2 seconds]) compared to both robotic groups (P < 0.001).
Conclusions:
In this preclinical study, the proof-of-concept for telerobotic ICA was successfully demonstrated. Furthermore, the current limits of telerobotic capabilities were tested by conducting ICA between separate continents and showing that transatlantic telerobotic navigation of endovascular devices is now technically possible.
More Related Videos
05:31Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies