Related Experiment Video
Updated: Jun 2, 2025

Swin-PSAxialNet: An Efficient Multi-Organ Segmentation Technique
Published on: July 5, 2024
Head and neck automatic multi-organ segmentation on Dual-Energy Computed Tomography
Anh Thu Lê1, Killian Sambourg1, Roger Sun1,2
1Université Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Background And Purpose:
Deep-learning-based automatic segmentation is widely used in radiation oncology to delineate organs-at-risk. Dual-energy CT (DECT) allows the reconstruction of enhanced contrast images that could help with manual and auto-delineation. This paper presents a performance evaluation of a commercial auto-segmentation software on image series generated by a DECT.
Material And Methods:
Different types of DECT images from seventy four head-and-neck (HN) patients were retrieved, including polyenergetic images at different voltages [80 kV reconstructed with a kernel corresponding to the commercial algorithm DirectDensity™ (PEI80-DD), 80 kV (PEI80), 120 kV-mixed (PEI120)] and a virtual-monoenergetic image at 40 keV (VMI40). Delineations used for treatment planning were considered as ground truth (GT) and were compared with the auto-segmentations performed on the 4 DECT images. A blinded qualitative evaluation of 3 structures (thyroid, left parotid, left nodes level II) was carried out. Performance metrics were calculated for thirteen HN structures to evaluate the auto-contours including dice similarity coefficient (DSC), 95th percentile Hausdorff distance (95HD) and mean surface distance (MSD).
Results:
We observed a high rate of low scores for PEI80-DD and VMI40 auto-segmentations on the thyroid and for GT and VMI40 contours on the nodes level II. All images received excellent scores for the parotid glands. The metrics comparison between GT and auto-segmented contours revealed that PEI80-DD had the highest DSC scores, significantly outperforming other reconstructed images for all organs (p < 0.05).
Conclusions:
The results indicate that the auto-contouring system cannot generalize to images derived from DECT acquisition. It is therefore crucial to identify which organs benefit from these acquisitions to adapt the training datasets accordingly.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022