Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

705
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
705
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

4.0K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
4.0K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

334
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
334
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

369
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
369
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

722
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
722
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

464
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
464

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Observations of Nocturnal Sulfuric Acid Formation in Pittsburgh, PA.

Environmental science & technology·2026
Same author

Optimization of Immune Checkpoint Blockade via a Multiscale Model System.

Computational and systems oncology·2025
Same author

Biogenic Volatile Organic Compounds from Pennsylvanian Lakes Sampled during the 2024 Algal Bloom Season.

ACS ES&T air·2025
Same author

Opportunities for machine learning and artificial intelligence in physiologically-based pharmacokinetic (PBPK) modeling.

Advanced drug delivery reviews·2025
Same author

Per-Event Uncertainty Quantification for Flow Cytometry Using Calibration Beads.

Cytometry. Part A : the journal of the International Society for Analytical Cytology·2025
Same author

Uncertainty Quantification of Fluorescence Signals in Flow Cytometry Part I: An Analytical Perspective Beyond Q and B.

Cytometry. Part A : the journal of the International Society for Analytical Cytology·2025
Same journal

Characterization of Alkane Oxidation Products in a Corona-Discharge Reactor Using Ammonia-Doped Ion Mobility-Mass Spectrometry.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Integration of a Modified Synchrotron Radiation Photoionization Time-of-Flight Mass Spectrometer with a Residual Gas Analyzer for Complementary Detection of Catalytic Products with Different Ionization Energies.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Screen for Tissue-Specific Markers of Drug-Induced Phospholipidosis Using Mass Spectrometry Imaging.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Molecular Framework Modification in Mass Spectrometry: Atom Exchange, Insertion, and Deletion.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Interlaboratory Comparison of Orbitrap Analyzers in OrbiSIMS: Noise Parameters, Intensity Scaling, and Detection Limits.

Journal of the American Society for Mass Spectrometry·2026
Same journal

Isotope-Coded Derivatization Enables Accurate LC-MS/MS Quantification of Urinary THC-COOH without Isotope-Labeled Cannabinoid Standards.

Journal of the American Society for Mass Spectrometry·2026
See all related articles

Related Experiment Video

Updated: Jun 2, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

12.7K

New Library-Based Methods for Nontargeted Compound Identification by GC-EI-MS.

Deborah F McGlynn1, Lindsay D Yee2, H Martin Garraffo3

  • 1Applied and Computational Mathematics Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States.

Journal of the American Society for Mass Spectrometry
|January 14, 2025
PubMed
Summary
This summary is machine-generated.

New methods improve compound identification in complex mixtures using mass spectral libraries. A novel median relative abundance measure aids in evaluating the likelihood of identifying unknown spectra from combustion samples.

More Related Videos

GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
11:06

GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil

Published on: May 19, 2012

16.9K
Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
09:04

Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow

Published on: April 18, 2019

12.4K

Related Experiment Videos

Last Updated: Jun 2, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

12.7K
GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
11:06

GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil

Published on: May 19, 2012

16.9K
Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
09:04

Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow

Published on: April 18, 2019

12.4K

Area of Science:

  • Analytical Chemistry
  • Environmental Science

Background:

  • Gas chromatography-mass spectrometry (GC-MS) is crucial for identifying compounds in complex mixtures.
  • Current GC-MS identification processes are often subjective, time-consuming, and result in many unidentified spectra.

Purpose of the Study:

  • To develop and evaluate new mass spectral library-based methods for enhanced compound identification.
  • To address the challenge of unidentified spectra in complex mixtures, particularly from combustion sources.

Main Methods:

  • Utilized mass spectral uniqueness, compound ubiquity, noise reduction, and retention index comparison.
  • Employed the NIST 2023 EI-MS Library and NIST MS PepSearch software with retention-index corrected Identity Search scoring.
  • Introduced Hybrid Similarity Search for identifying related compounds not directly in libraries and developed a median relative abundance measure.

Main Results:

  • Initial identification using NIST software was performed on a dataset of 4833 spectra from wildland fuel combustion.
  • Despite advanced methods, approximately 90% of spectra remained unidentified.
  • A new metric, median relative abundance, was developed to assess the probability of spectral identification.

Conclusions:

  • The developed methods offer improvements for compound identification in complex mixtures.
  • The median relative abundance metric provides a valuable tool for evaluating the confidence of spectral identifications.
  • Further research is needed to address the high percentage of unidentified spectra in challenging samples.