Ischemic preconditioning in arterialized venous flap: Temperature effects and monitoring
Rani Septrina1, Ronny Lesmana2, Reno Rudiman1
1Department of Surgery, Faculty of Medicine Universitas Padjadjaran, Bandung, Indonesia.
Introduction:
Arterialized venous flap, like any other flap, will undergo an ischemic reperfusion injury during its transfer process. To overcome this, ischemic preconditioning can be done to provide protection and enhanced flap survival. One of the reliable parameters of flap survival is its temperature. However, there was no recorded data regarding AVF's temperature or its monitoring. This research aimed to demonstrate the temperature effect of ischemic preconditioning on arterialized venous flap.
Method:
Male Wistar Rats were randomly divided into 4 groups, consisting of 6 negative control groups, 8 positive control group (PS) rats that underwent an anastomosis of the superficial epigastric artery to the superficial epigastric vein, 8 experimental rat group 1 (EX1) that underwent 3 cycles of 5 minutes pre-anastomosis clamping with 3 cycles of 5 minutes each, and 8 experimental rats' group 2 (EX2) with 3 cycles of 10 minutes. Flap's temperature was observed preoperatively and postoperatively from day 1 to day 7, day 14, and day 21 with an android-based thermal camera and recorded in Celsius degrees.
Results:
All the flaps (N= 26) were vital. The temperature drop was seen in all anastomosed flaps compared to the negative control (30.37 vs. 25.08 vs. 23.77 vs. 25.27, p<0.05). A significant increase in temperature occurred on days 4 to 6 in Ex1 (33.62±1.820, 33.62±1.820, 32.40±1.627; p<0.05). As in the temperature trend, Ex2 is shown to have a stable temperature from day 2 until 21.
Conclusion:
This study has recorded an increase in temperature in the early days of the creation of the arterialized venous flap at various timings of ischemic preconditioning. The flap's monitoring was easily observed with a thermal camera that can be implemented in humans.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection