Related Experiment Video
Updated: May 7, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
Validation of a Visual Field Prediction Tool for Glaucoma: A Multicenter Study Involving Patients With Glaucoma in
Arlen Dean1, Dun Jack Fu2, Mohammad Zhalechian3
1From the Department of Industrial and Operations Engineering (A.D., M.P.V.O., M.S.L.), University of Michigan College of Engineering, Ann Arbor, Michigan, USA.
Purpose:
A previously developed machine-learning approach with Kalman filtering technology accurately predicted the disease trajectory for patients with various glaucoma types and severities using clinical trial data. This study assesses performance of the KF approach with real-world data.
Design:
Retrospective cohort study.
Methods:
We tested the performance of a previously validated KF model (PKF) initially trained using data from the African Descent and Glaucoma Evaluation Study and the Diagnostic Innovations in Glaucoma Study in patients with different types and severities of glaucoma receiving care in the United Kingdom (UK), comparing the predictive accuracy to 2 conventional linear regression (LR) models and a newly developed KF trained on UK patients (UK-KF).
Results:
A total of 3116 patients with open-angle glaucoma or suspects were divided into training (n=1584) and testing (n=1532) sets. The predictive accuracy for MD within 2.5 dB of the observed value at 60 months' follow-up for PKF (75.7%) was substantially better than those for the LR models (P < .01 for both) and similar to that for UK-KF (75.2%, P = .70). The proportion of MD predictions in the 95% repeatability intervals at 60 months' follow-up for PKF (67.9%) was higher than those for the LR models (40.2%, 40.9%) and similar to that for UK-KF (71.4%).
Conclusions:
This study validates the performance of our previously developed KF model on a real-world, multicenter patient population. Our model substantially outperforms the current clinical standard (LR) and forecasts well for patients with different glaucoma types and severities. This study supports the generalizability of PKF performance and supports prospective study of implementation into clinical practice.
More Related Videos
07:45Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
07:12Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment