Borderline Findings in O-(2-[18F]-Fluoroethyl)-l-Tyrosine PET of Patients with Suspected Glioma Relapse: Role in
Karl-Josef Langen1,2,3, Gabriele Stoffels4, Christian P Filss4,2
1Institute of Neuroscience and Medicine (INM-3/INM-4/INM-5/INM-11), Forschungszentrum Jülich, Jülich, Germany; k.j.langen@fz-juelich.de.
Abstract:
One of the most common clinical indications for amino acid PET using the tracer O-(2-[18F]-fluoroethyl)-l-tyrosine (18F-FET) is the differentiation of tumor relapse from treatment-related changes in patients with gliomas. A subset of patients may present with an uptake of 18F-FET close to recommended threshold values. The goal of this study was to investigate the frequency of borderline cases and the role of quantitative 18F-FET PET parameters in this situation. Methods: We retrospectively identified 439 patients with pretreated gliomas who underwent 18F-FET PET for suspected tumor relapse and in whom the final diagnoses were confirmed by histopathology (n = 175) or clinical course (n = 264). Two experienced nuclear medicine physicians, masked to the final diagnoses, evaluated visually the PET scans by consensus. The findings were classified into 3 categories: clearly positive findings, borderline findings, or clearly negative findings. The diagnostic performance of established 18F-FET PET parameters (i.e., tumor-to-brain ratio [TBR], time-to-peak ratio, slope, intercept) was evaluated separately for these 3 groups using receiver operating characteristics analyses. Results: In the visual analysis, 18F-FET uptake was classified as clearly negative in 67 patients (15%), clearly positive in 234 patients (53%), and borderline in 136 patients (31%), with averaged mean TBR values of 1.5, 2.3, and 1.9, respectively. Receiver operating characteristics analysis showed a high accuracy for TBR values in patients rated as clearly positive or negative in visual rating (area under curve [AUC], 0.84-0.86), whereas the diagnostic performance of TBR values in borderline cases according to visual analysis was significantly lower (AUC, <0.60). Using TBR values ± 10% above or below the cutoff values increased the AUC by approximately 10% (AUC, 0.82-0.84). Conclusion: A considerable number of patients may present with borderline findings in 18F-FET PET. In these patients, quantitative parameters should be used with caution for decision-making. The use of TBR values above or below the range of the cutoff values ±10% may increase the reliability of quantitative parameters to differentiate between tumor relapse and treatment-related changes.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)