Related Experiment Video
Updated: Jun 2, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Electrical impedance tomography meets reduced order modelling: a framework for faster and more reliable electrical
Matthew R Walker1, Mariano Fernández-Corazza2, Sergei Turovets3
1Matthew Walker and Leandro Beltrachini are with Cardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff CF24 4HQ, United Kingdom.
Abstract:
Objective.Inclusion of individualised electrical conductivities of head tissues is crucial for the accuracy of electrical source imaging techniques based on electro/magnetoencephalography and the efficacy of transcranial electrical stimulation. Parametric electrical impedance tomography (pEIT) is a method to cheaply and non-invasively estimate them using electrode arrays on the scalp to apply currents and measure the resulting potential distribution. Conductivities are then estimated by iteratively fitting a forward model to the measurements, incurring a prohibitive computational cost that is generally lowered at the expense of accuracy. Reducing the computational cost associated with the forward solutions would improve the accessibility of this method and unlock new capabilities.Approach.We introduce reduced order modelling (ROM) to massively speed up the calculations of these solutions for arbitrary conductivity values.Main results.We demonstrate this new ROM-pEIT framework using a realistic head model with six tissue compartments, with minimal errors in both the approximated numerical solutions and conductivity estimations. We show that the computational complexity required to reach a multi-parameter estimation with a negligible relative error is reduced by more than an order of magnitude when using this framework. Furthermore, we illustrate the benefits of this new framework in a number of practical cases, including its application to real pEIT data from three subjects.Significance.Results suggest that this framework can transform the use of pEIT for seeking personalised head conductivities, making it a valuable tool for researchers and clinicians.
More Related Videos
08:41Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
Published on: October 10, 2018
10:51Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance
Published on: September 26, 2017
Related Concept Videos
Bode Plots Construction
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Impedance Combination