Spontaneous otoacoustic emission as a novel method to screen pulsatile tinnitus caused by sigmoid sinus wall
Xu Liu1,2, Yue-Lin Hsieh1,2, Yunfeng Wang1,2
1ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.
Objective:
To evaluate the diagnostic potential of spontaneous otoacoustic emissions (SOAE), distortion product otoacoustic emissions (DPOAE), and pure-tone audiometry (PTA) in patients with pulsatile tinnitus (PT) caused by sigmoid sinus wall anomalies (SSWA).
Methods:
This study included 20 PT patients and 20 matched healthy controls. SOAE, DPOAE, and PTA were assessed before and after compression of the internal jugular vein. Statistical analysis included paired t-tests to compare differences in SOAE amplitude, DPOAE signal-to-noise ratios, and PTA thresholds, while independent t-tests assessed age differences, and one-way ANOVA evaluated mean PTA thresholds.
Results:
SOAE amplitudes were significantly higher in ipsilesional ears compared to contralesional and control ears. DPOAE showed a significant difference in 0.5 kHz S/N-ratio between ipsilesional and contralesional ears. PTA revealed higher thresholds in ipsilesional ears at low frequencies, with differences decreasing after compression.
Conclusion:
Besides radiological modalities, SOAE is a sensitive tool for diagnosing and assessing the severity of PT in patients with SSWA, with DPOAE and PTA providing supplementary information. These findings suggest a multimodal approach for the diagnosis of PT related to SSWA.
More Related Videos
07:06Endaural Endoscopic Atticoantrotomy Retrograde Mastoidectomy using a Constant Suction Bone-drilling Technique
Published on: May 23, 2021
09:07Author Spotlight: Advancing Endoscopic Ossiculoplasty – Techniques, Innovations, and Practical Guidance for Clinical Integration
Published on: January 26, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias