Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inverse z-Transform by Partial Fraction Expansion01:20

Inverse z-Transform by Partial Fraction Expansion

278
The inverse z-transform is a crucial technique for converting a function from its z-domain representation back to the time domain. One effective method for finding the inverse z-transform is the Partial Fraction Method, which involves decomposing a function into simpler fractions with distinct coefficients. These fractions correspond to known z-transform pairs, facilitating the inverse transformation process.
To begin the process, the poles of the function are identified and the function is...
278
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

167
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
167
Inverting and Non-inverting OpAmps01:20

Inverting and Non-inverting OpAmps

557
In an inverting amplifier, the input voltage is connected through a resistor to the inverting terminal. Meanwhile, the non-inverting terminal is grounded and a feedback resistor is established between the inverting and output terminal, as depicted in Figure 1.
557
Lossy Lines and Overvoltages01:22

Lossy Lines and Overvoltages

81
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
81
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

5.6K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
5.6K
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

60
Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
60

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The effect of anthropometrics and maturity status on youth rugby head impact biomechanics.

Journal of biomechanics·2026
Same author

Thalamic nuclei insights into Alzheimer's disease.

bioRxiv : the preprint server for biology·2026
Same author

Quantitative MRI Biomarkers of Myelin: Cross-Validation and Diagnostic Performance in Multiple Sclerosis.

NMR in biomedicine·2026
Same author

Multimodal MRI Reveals Brain Structural Differences and Executive Dysfunction in Early Methamphetamine Abstinence.

Brain and behavior·2026
Same author

Plasma pTau181 is associated with subjective cognitive concerns but not objective cognitive decline or structural brain integrity measures in midlife.

GeroScience·2026
Same author

Whiteout sign on dSIR MRI: A case series highlighting symptom-associated white matter changes not observed on standard T<sub>2</sub>-FLAIR.

Brain injury·2026
Same journal

Incremental diagnostic value of microstructural time-dependent diffusion MRI in differentiating PCNSL from glioblastoma over conventional MRI.

Magnetic resonance imaging·2026
Same journal

Enhanced motion compensation for free-breathing dynamic contrast-enhanced MRI with GROG-facilitated bunch phase encoding and Golden angle radial sampling.

Magnetic resonance imaging·2026
Same journal

The allegory of the cave: 10 years of AI shadows in radiology.

Magnetic resonance imaging·2026
Same journal

Conversion of 3 T liver, spleen, pancreas, and kidney R2* measurements to 1.5 T R2* equivalents: Validation of a theoretical framework.

Magnetic resonance imaging·2026
Same journal

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

Magnetic resonance imaging·2026
Same journal

Bone marrow fat fraction and R2* in sickle cell disease: Associations with hemolysis, iron metabolism, and disease severity.

Magnetic resonance imaging·2026
See all related articles

Related Experiment Video

Updated: Jun 1, 2025

Sample Drift Correction Following 4D Confocal Time-lapse Imaging
10:04

Sample Drift Correction Following 4D Confocal Time-lapse Imaging

Published on: April 12, 2014

16.3K

Log subtracted inversion recovery.

Mark Bydder1, Daniel M Cornfeld2, Tracy R Melzer3

  • 1Mātai Medical Research Institute, Tairāwhiti, Gisborne, New Zealand.

Magnetic Resonance Imaging
|January 18, 2025
PubMed
Summary
This summary is machine-generated.

New magnetic resonance imaging (MRI) methods use two inversion times (TIs) to create enhanced T1 contrast images. This novel two-point inversion recovery (IR) technique improves anatomical visualization in challenging MRI regions.

Keywords:
FLAWSInversion recoveryMP2RAGET1 mappingdSIR

More Related Videos

Fluorescence Recovery after Photobleaching of Yellow Fluorescent Protein Tagged p62 in Aggresome-like Induced Structures
12:58

Fluorescence Recovery after Photobleaching of Yellow Fluorescent Protein Tagged p62 in Aggresome-like Induced Structures

Published on: March 26, 2019

14.8K
Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
06:46

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

Published on: August 25, 2016

11.3K

Related Experiment Videos

Last Updated: Jun 1, 2025

Sample Drift Correction Following 4D Confocal Time-lapse Imaging
10:04

Sample Drift Correction Following 4D Confocal Time-lapse Imaging

Published on: April 12, 2014

16.3K
Fluorescence Recovery after Photobleaching of Yellow Fluorescent Protein Tagged p62 in Aggresome-like Induced Structures
12:58

Fluorescence Recovery after Photobleaching of Yellow Fluorescent Protein Tagged p62 in Aggresome-like Induced Structures

Published on: March 26, 2019

14.8K
Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
06:46

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

Published on: August 25, 2016

11.3K

Area of Science:

  • Medical Imaging
  • Radiology
  • Biophysics

Background:

  • Conventional inversion recovery (IR) magnetic resonance imaging (MRI) typically uses a single inversion time (TI).
  • Limitations exist in differentiating tissues with similar T1 relaxation times using standard IR techniques.
  • Advanced MRI techniques are sought to enhance contrast and anatomical detail.

Purpose of the Study:

  • To introduce and evaluate a novel two-point IR technique for improved T1 contrast imaging.
  • To demonstrate the utility of this method in visualizing anatomical structures not well-differentiated by conventional IR MRI.
  • To analyze the T1 response characteristics of the proposed technique.

Main Methods:

  • Development of a novel two-point IR sequence utilizing subtraction of log images.
  • Acquisition of IR images at two distinct inversion times (TIs).
  • Application of basic mathematical operations (multiplication, addition, subtraction, division) for image reconstruction.

Main Results:

  • The novel two-point IR technique exhibits a near-linear response to T1 relaxation times between nullpoints.
  • A sharp peak in signal intensity is observed at the nullpoints.
  • The method generates a bright isoT1 contour at tissue interfaces with partial volume effects, enhancing visualization.

Conclusions:

  • The described two-point IR technique offers superior T1 contrast compared to conventional methods.
  • This technique effectively delineates anatomical boundaries in regions with poor signal differentiation.
  • The method holds potential for improved diagnostic accuracy in MRI by providing enhanced anatomical information.