HEMA-free versus HEMA-containing adhesive systems: a systematic review
Esraa Abdelkhalek1, Hamdi H Hamama2, Salah H Mahmoud1
1Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Postal Code, 35516, Egypt.
HEMA-free dental adhesives show comparable retention to HEMA-containing ones. However, their impact on marginal adaptation and discoloration requires further long-term clinical investigation.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Clinical Dentistry
Background:
- Hydrophilic 2-hydroxyethyl methacrylate (HEMA) in dental adhesives enhances wettability but risks hydrolytic degradation.
- HEMA-free adhesive systems are emerging to mitigate degradation issues.
- Potential phase separation between hydrophobic and hydrophilic components is a concern in HEMA-free systems.
Purpose of the Study:
- To systematically review and compare the clinical performance of HEMA-free dental adhesive systems against HEMA-containing systems.
- To evaluate retention, marginal adaptation, and discoloration of HEMA-free adhesives in direct resin composite restorations.
Main Methods:
- Systematic literature search of MEDLINE/PubMed for clinical studies (2013-2023).
- Inclusion criteria: empirical data, HEMA-free adhesives, direct resin composite restorations, minimum 2-year follow-up in permanent dentition.
- Risk of bias assessment using modified Cochrane Collaboration tool.
Main Results:
- Seven studies met the inclusion criteria from 147 initially identified.
- Most studies reported no significant difference in retention between HEMA-free and HEMA-containing adhesives.
- Conflicting results were noted for marginal adaptation and discoloration.
Conclusions:
- HEMA-free adhesive systems demonstrate satisfactory clinical retention.
- Further long-term studies are necessary to confirm clinical performance regarding marginal adaptation and discoloration.
- The clinical efficacy of HEMA-free adhesives warrants continued investigation.