A Wearable Prototype Measuring PtcCO2 and SpO2
Kleo Golemi1, Evan Apinis1, Isil Isiksalan1
1Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Abstract:
The proper functioning of the respiratory system is evaluated by monitoring the exchange of blood oxygen and carbon dioxide. While wearable devices for monitoring both blood oxygen and carbon dioxide are emerging, wearable carbon dioxide monitors remain relatively rare. This paper introduces a novel wearable prototype that integrates the measurement of transcutaneous carbon dioxide and peripheral blood oxygen saturation on a miniaturized custom-designed printed circuit board. The device employs a fluorescent sensing film consisting of two distinct luminophore types and utilizes the time-domain dual lifetime referencing technique to enhance measurement accuracy by mitigating the effects of confounding factors. Thorough testing on human subjects validated the prototype's functionality, comparing its performance against commercial clinical devices. The prototype effectively tracked changes in transcutaneous carbon dioxide induced by hyperventilation, with a resolution as low as 1 mmHg. Additionally, blood oxygen saturation measurements were tested on human subjects to compare our prototypes' performance to that of clinical devices. The results confirm the potential of the proposed novel wearable for prolonged use with minimal maintenance and underscore its significance in advancing wearable health monitoring technologies.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...