Related Experiment Video
Updated: May 31, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
The effect of increased vascular afterload measures on flow rate and survival in severe aortic stenosis
Sara L Hungerford1,2,3, Ning Song4,5,6, Brandon Loo5
1The CardioVascular Center, Tufts Medical Center, 800 Washington Street, Boston, MA 02111, USA.
Aims:
Although an association between the systemic circulation and transaortic flow rate (TFR) is frequently hypothesized in patients with aortic stenosis (AS), it has not been demonstrated previously. We sought to explore the relationship between blood pressure (BP), vascular afterload measures, clinical history of hypertension, TFR, and survival in patients with severe AS (aortic valve area ≤ 1 cm²).
Methods And Results:
We studied 323 patients ≥ 65 years (110 prospective, 213 registry analysis) who underwent transcatheter aortic valve replacement over a 5-year period. Aortic flow was obtained by Doppler echocardiography, with TFR calculated using a mathematical derivation method. A BP ≥ 140/90 mmHg and/or mean arterial pressure ≥ 90 mmHg was considered hypertensive. Simultaneous pressure-flow analysis demonstrated that higher systolic BP (ß -0.545; P = 0.01†), pulse pressure (ß -0.545; P = 0.01†), vascular resistance (ß -0.02; P = 0.041), characteristic impedance (ß -0.27; P = 0.01), and lower arterial compliance (ß 32.73; P < 0.001†) were associated with reduced TFR in linear regression. In registry analysis, TFR was lower in those with a history of hypertension (223 ± 67 vs. 244 ± 77 mL/s; r -0.138; P = 0.045), coronary artery disease (CAD, P < 0.01), dialysis dependency (P < 0.01), and with increased anti-hypertensive medication use (P = 0.04), of which CAD (ß -28.5; P = 0.08†) and dialysis dependency (ß -68.5; P = 0.04†) remained significant in linear regression. A TFR ≤ 210 mL/s in normotensive patients was the strongest predictor of mortality (73.3% vs. 86.7%; P = 0.043; † denotes adjusted).
Conclusion:
Elevated vascular afterload measures and comorbidities linked to arteriosclerosis and/or degenerative aortic stiffening independently reduce flow rates in severe AS. A TFR ≤ 210 mL/s predicts mortality but improves with BP assessment during evaluation.
More Related Videos
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Blood Flow