Related Experiment Video
Updated: May 5, 2026

Synthesis and Characterization of Functionalized Metal-organic Frameworks
Published on: September 5, 2014
Electron Microscopy Reveals Inhomogeneous Adsorption of Iodine and Concurrent Defect Formation in a Metal-Organic
Ying Liu1, Dong Liu1, Zhaohui Liu1
1Multi-scale Porous Materials Center, Institute of Advanced Interdisciplinary Studies & School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, P. R. China.
Abstract:
Adsorption behaviors are typically examined through adsorption isotherms, which measure the average adsorption amount as a function of partial pressure or time. However, this method is incapable of identifying inhomogeneities across the adsorbent, which may occur in the presence of strong intermolecular interactions of the adsorbate. In this study, we visualize the adsorption of molecular iodine (I2) in the metal-organic framework material MFM-300(Sc) using high-resolution scanning transmission electron microscopy (STEM). Our observations demonstrate that, counterintuitively, I2 adsorption in MFM-300(Sc) occurs in an inhomogeneous manner, regardless of the I2 uptake level. Even at adsorption saturation, corresponding to an average of 23 iodine atoms per unit cell, MOF channels with significantly varying iodine contents─from nearly empty to densely filled─coexist. Image simulations suggest that the most densely packed I2 may locally form the previously proposed triple-helix structure, corresponding to up to 142 iodine atoms per unit cell. Furthermore, STEM imaging reveals that I2 adsorption can induce the formation of structural defects, such as edge dislocations and stacking faults, within the MOF framework. These defects persist even after the complete removal of I2 molecules. Additionally, we have developed a surfactant-capping strategy to minimize the release of adsorbed I2 from MFM-300(Sc) and validated its effectiveness using STEM imaging.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Transmission Electron Microscopy
Imperfections in Crystal Structure: Point, Line and Plane Defects
Imperfections in Crystal Structure: Stoichiometric Point Defects
Imperfections in Crystal Structure: Non-Stoichiometric Defects

