Evaluation of Non-Invasive Hemoglobin Monitoring in Perioperative Patients: A Retrospective Study of the Rad-67TM
Philipp Helmer1, Andreas Steinisch1, Sebastian Hottenrott1
1Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
Abstract:
Background: Hemoglobin (Hb) is a crucial parameter in perioperative care due to its essential role for oxygen transport and tissue oxygenation. Accurate Hb monitoring allows for timely interventions to address perioperative anemia and, thus, prevent morbidity and mortality. Traditional Hb measurements rely on invasive blood sampling, which significantly contributes to iatrogenic anemia and poses discomfort and increased infection risks. The advent of non-invasive devices like Masimo's Rad-67™, which measures Hb using pulse CO-oximetry (SpHb), offers a promising alternative. This study evaluates the accuracy of SpHb compared to clinical standard blood gas analysis (BGA) in perioperative patients. Methods: This retrospective study analyzed 335 paired Hb measurements with an interval <15 min between SpHb and BGA in the operating theater and post-anesthesia care unit of a university hospital. Patients experiencing hemodynamic instability, acute bleeding, or critical care were excluded. Statistical analysis included Bland-Altman plots and Pearson correlation coefficients (PCCs) to assess the agreement between SpHb and BGA. Potential confounders, e.g., patient age, skin temperature, sex, perfusion index (PI), and atrial fibrillation, were also analyzed. Results: The bias of the SpHb compared to BGA according to Bland-Altman was 0.00 g/dL, with limits of agreement ranging from -2.70 to 2.45 g/dL. A strong correlation was observed (r = 0.79). Overall, 57.6% of the paired measurements showed a deviation between the two methods of ≤±1 g/dL; however, this applied to only 33.3% of the anemic patients. Modified Clark's Error Grid analysis showed 85.4% of values fell within clinically acceptable limits. Sex was found to have a statistically significant, but not clinically relevant, effect on accuracy (p = 0.02). Conclusions: The Rad-67TM demonstrates reasonable accuracy for non-invasive SpHb, but exhibits significant discrepancies in anemic patients with overestimating low values. While it offers potential for reducing iatrogenic blood loss, SpHb so far should not replace BGA in critical clinical decision-making.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...