Non-Intrusive Monitoring of Vital Signs in the Lower Limbs Using Optical Sensors
Joana Simões1, Regina Oliveira1, Florinda M Costa1
1Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal.
Sensors (Basel, Switzerland)
|January 25, 2025
Summary
This study developed a novel system using thigh-worn sensors for continuous, invisible health monitoring. It accurately measures heart rate (HR) and respiratory rate (RR) in real-time, demonstrating viability for lower limb vital sign tracking.
Area of Science:
- Biomedical Engineering
- Wearable Technology
- Health Monitoring
Background:
- Invisible health monitoring is gaining global scientific interest.
- Sensorizing everyday objects enables continuous health data collection without altering user routines.
Purpose of the Study:
- To assess the feasibility of photoplethysmography (PPG) acquisition in the lower limbs for continuous vital sign monitoring.
- To develop and validate a system for real-time heart rate (HR) and respiratory rate (RR) measurement using PPG signals from the thigh.
Main Methods:
- Utilized two MAX30102 sensors placed on the back of the thigh to acquire PPG signals.
- Conducted a proof-of-concept study with 17 volunteers (ages 22-40).
- Compared the developed system's measurements against reference sensors.
Main Results:
- Achieved a Pearson correlation coefficient of r = 0.92 for HR and r = 0.77 for RR.
- Obtained a mean difference of 1.2 bpm for HR and 0.9 rpm for RR compared to reference sensors.
- Demonstrated system accuracies of 95.9% for HR and 91.3% for RR.
Conclusions:
- The developed system shows significant viability for continuous and real-time vital sign monitoring in the lower limbs.
- This approach offers a non-intrusive method for health tracking through sensorization of everyday objects.
- Further research can explore broader applications of lower limb PPG for remote patient monitoring.
Related Concept Videos
Pulse rhythm
754
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
754
Assessing Blood pressure in the Leg
1.9K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
1.9K
Guidelines For Measuring Vital Signs
1.5K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
1.5K
Equipments Used To Measure Blood Pressure
816
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
816
Pulse Assessment Sites
914
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
914
Assessing Blood pressure using a doppler ultrasound
1.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.2K