Geometry-Based Synchrosqueezing S-Transform with Shifted Instantaneous Frequency Estimator Applied to Gearbox Fault

Xinping Zhu1,2, Wuxi Shi1, Zhongxing Huang3

  • 1School of Mechanical Engineering, Tiangong University, Tianjin 300387, China.

PubMed

Related Concept Videos

Simplified Synchronous Machine Model01:30

Simplified Synchronous Machine Model

The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
175
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
72
Transmission Shafts: Problem Solving01:09

Transmission Shafts: Problem Solving

Designing a solid shaft that transmits power from a motor to a machine tool involves a series of calculations to ensure the shaft can withstand the stresses applied by bending moments and torques. First, calculate the torque exerted on the gear, considering the power transmitted by the shaft and its rotational speed. Following this, compute the tangential forces acting on the gears, which directly relate to the torque and the gear radius.
Next, use bending moment diagrams for the shaft to...
207
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
114
The Swing Equation01:21

The Swing Equation

The Swing Equation is a fundamental tool in power system dynamics, especially for analyzing the behavior of generating units like three-phase synchronous generators. This equation emerges from applying Newton's second law to the rotor of a generator, encompassing factors such as inertia, angular acceleration, and the interplay between mechanical and electrical torques.
In a steady-state operation, the mechanical torque (Τm) supplied to the generator is balanced by the electrical torque...
301
Design of Transmission Shafts01:16

Design of Transmission Shafts

The design of a transmission shaft is governed by two primary specifications: the power it transmits and its rotational speed. These parameters guide the selection of the shaft's material and cross-sectional dimensions, ensuring that the material's maximum shearing stress remains within the elastic limit while transmitting the desired power at the given speed. The system's power is intrinsically linked to the applied torque. The torque applied to the shaft can be calculated by...
281