Related Experiment Video
Updated: May 30, 2025

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Breast ultrasound imaging systems performance evaluation using novel Contrast-Detail (C-D) and Anechoic-Target (A-T)
S Cournane1, A J Fagan2, J E Browne2
1St. Vincent's University Hospital Dublin Ireland; School of Physics University College Dublin Dublin Ireland.
Abstract:
Ultrasound imaging plays an important role in the early detection and management of breast cancer. This study aimed to evaluate the imaging performance of a range of clinically-used breast ultrasound systems using a set of novel spherical lesion contrast-detail (C-D) and anechoic-target (A-T) phantoms.
Methods:
C-D and A-T phantoms were imaged using a range of clinical breast ultrasound systems and imaging modes. A novel sensitive imaging performance metric, the Detectability Score (DS), was proposed which encompasses the Lesion Contrast to Noise Ratio (LCNR) weighted by the lesion depth and diameter. A geometry-based theoretical model comparing LCNR measured using spherical and cylindrical phantom anechoic/lesion targets was developed to investigate the influence of slice thickness on focal lesion detectability.
Results:
LCNR and DS metrics derived from phantom image measurments were capable of differentiating the imaging performance of a range of ultrasound systems and advanced imaging modes, with the -2 dB contrast lesion targets offered as the most challenging to resolve. The geometry-based theoretical model, validated against phantom measurements, demonstrated the significant influence of slice thickness on focal lesion detectability, highlighting the need for increased availability of low contrast resolution spherical target phantoms for clinically realistic performance evaluation.
Conclusions:
The performance metrics coupled with the -1 dB contrast targets provide scope for evaluating future technological improvements in ultrasound systems. Given the high dependence of breast cancer care on high quality ultrasound imaging techniques, there is a need for evaluating imaging performance using clinically relevant test objects.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...