Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

330
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
330
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

454
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
454
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

396
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
396
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

365
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
365

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Laser-Guided Self-Rolled Magnetic Microrobots for Targeted Biofilm Eradication in Severely Infected Medical Stents.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Isthmin-1 is a key regulator of induced pluripotent stem cell-derived cardiomyocytes maturation through activation of p53 signaling.

Journal of molecular and cellular cardiology·2026
Same author

Assessing climate change-induced precipitation effects on the long-term reliability of common final landfill cover systems.

Water research·2026
Same author

Aromatic protein-like recognition enables rapid prediction of sludge deep dewaterability.

Bioresource technology·2026
Same author

Recent Advances and Prospects in Skin-Integrated Electronics: Flexible Sensing Systems for Robotics, Human-Machine Interaction, and Health Monitoring.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Laser-Engineered Ag Nanoparticle on Carbon Cloth Electrodes for Enzyme-Free Electrochemical NAD<sup>+</sup> Detection.

Small (Weinheim an der Bergstrasse, Germany)·2026

Related Experiment Video

Updated: May 30, 2025

Fruit Volatile Analysis Using an Electronic Nose
11:02

Fruit Volatile Analysis Using an Electronic Nose

Published on: March 30, 2012

21.3K

Hierarchical Porous Aggregate-Enabled Chromatography-Inspired Single-Sensor E-Nose for Volatile Monitoring.

Haowen Guo1, Taoping Liu2, Xingchun Zhai1

  • 1School of Chemistry and Molecular Engineering, In Situ Devices Research Center, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China.

ACS Sensors
|January 27, 2025
PubMed
Summary

This study presents a novel, cost-effective electronic nose (e-nose) for monitoring volatile organic compounds (VOCs). The portable device offers rapid and precise VOC detection, ideal for point-of-care testing applications.

Keywords:
POCTVOCchromatography-inspirede-nosehierarchical porous aggregate

More Related Videos

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
08:23

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry

Published on: March 9, 2018

8.9K
Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase
09:53

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase

Published on: April 23, 2019

7.0K

Related Experiment Videos

Last Updated: May 30, 2025

Fruit Volatile Analysis Using an Electronic Nose
11:02

Fruit Volatile Analysis Using an Electronic Nose

Published on: March 30, 2012

21.3K
Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
08:23

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry

Published on: March 9, 2018

8.9K
Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase
09:53

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase

Published on: April 23, 2019

7.0K

Area of Science:

  • Materials Science
  • Chemical Sensing
  • Nanotechnology

Background:

  • Volatile organic compounds (VOCs) monitoring is vital for safety and health.
  • Traditional methods and conventional e-noses have limitations in VOC detection.
  • There is a need for cost-effective, portable, and precise VOC monitoring solutions.

Purpose of the Study:

  • To develop a chromatography-inspired single-sensor (CISS) electronic nose (e-nose) for efficient VOC monitoring.
  • To engineer a novel sensor material (CuP@G) with enhanced chemoresistive properties.
  • To create a portable and affordable e-nose suitable for point-of-care testing (POCT).

Main Methods:

  • Fabrication of a hierarchical porous multicomponent aggregate (CuP@G) from Cu2+-polydopamine and reduced graphene oxide.
  • Laser processing to create a grooved laser-induced graphene interdigitated electrode.
  • Integration of the sensor material and electrode into a compact laser-engraved microchamber to form the CISS e-nose.

Main Results:

  • The developed CISS e-nose demonstrated swift, reversible, and precise detection of various VOCs.
  • The sensor material (CuP@G) exhibited enhanced chemoresistive properties.
  • The resulting e-nose module is affordable, portable, and suitable for POCT.

Conclusions:

  • The developed CISS e-nose offers a streamlined and cost-effective solution for VOC monitoring.
  • This technology advances the development of proficient and accessible e-nose systems.
  • The portable and precise nature of the e-nose makes it ideal for real-world safety and health applications.