In Situ Analysis of Li Plating and Stripping Behaviors Under Dynamic Current Conditions for Realistic Application

Yanpeng Guo1, Xinqi Wei1, Cheng Zeng1

  • 1State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, 430074, China.

Related Concept Videos

Electrogravimetric Analysis: Overview01:30

Electrogravimetric Analysis: Overview

Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
198
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
154
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
168
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
127
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
216
Electrodeposition01:08

Electrodeposition

Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...