Related Experiment Video
Updated: May 30, 2025

A Novel Method: Super-selective Adrenal Venous Sampling
Published on: September 15, 2017
High-resolution 0.25 mm Detector CT Has Limited Impact on Right Adrenal Vein Detectability in Preprocedural Contrast
Hiroyuki Morisaka1, Akira Imaizumi1,2, Tihan Wumu1
1Department of Radiology, University of Yamanashi, Chuo, Yamanashi.
Objective:
This study aims to identify factors associated with the detectability of the right adrenal vein (RAV) on preoperative contrast-enhanced CT scans of adrenal venous sampling (AVS) in the era of high-resolution CT (HRCT).
Materials And Methods:
In this retrospective study, 36 patients (15 men and 21 women; mean age, 56 y) who underwent preoperative contrast-enhanced CT [11 patients in HRCT with 0.25 mm detector matrix (Cannon Medical Systems) and 25 patients in conventional multidetector CT with 0.5 mm matrix] were included. A contrast agent dose of 600 mgI/kg was injected, and CT images were acquired at a fixed scan delay of 50 and 80 seconds. Adrenal venography and venous sampling were performed for the diagnosis of suspected primary hyperaldosteronism. The qualitative detectability of RAV on preoperative CT was assessed with adrenal venography as a reference. Clinical and imaging factors associated with a good detectability of RAV were analyzed via regression analysis. Optimal acquisition timing was assessed by analyzing the time-intensity curve and contrast enhancement pattern of the inferior vena cava using CT data from a separate cohort (n=5).
Results:
The qualitative detectability of RAV was deemed good in 15 patients and poor in 21 patients. Regression analysis revealed that only heterogeneous enhancement of inferior vena cava with bolus high attenuation, corresponding to an optimal acquisition timing from time-intensity curve analysis, was associated with a good detectability of RAV (odds ratio, 5.06). The use of HRCT was not statistically significant.
Conclusions:
Optimal acquisition timing is a crucial factor for the detectability of RAV in preprocedural CT for AVS, while high-resolution 0.25 detector CT appears to have limited significance.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021