Related Experiment Video
Updated: Jul 18, 2026

Methods to Quantify Pharmacologically Induced Alterations in Motor Function in Human Incomplete SCI
Published on: April 18, 2011
Impact of Vibrations and Rapid Decelerations on SemontPLUS Maneuver Efficacy: An In Vitro Study
Miranda Morrison1, Aurelia Bucciarelli2, Athanasia Korda1
1Department of Otorhinolaryngology, Head and Neck Surgery, Inselspital, University Hospital Bern and University of Bern, Bern, Switzerland.
Objective:
We aimed to investigate the effect of adding "rapid decelerations" and "vibrations" during a SemontPLUS maneuver on the dynamics of the inner ear and the success rate of canalolithiasis repositioning.
Methods:
We used a previously described upscaled (5×) in vitro model of the posterior semicircular canal of the inner ear to analyze the trajectory of a single and clumped surrogate otolith particle (metallic sphere) during a SemontPLUS maneuver (-60 degrees below earth horizontal) on a repositioning chair (TRV). We compared the angular displacement of these particles with and without the application of "vibrations" or "rapid decelerations" using TRV. We recorded the success rates of the SemontPLUS maneuver for each condition.
Results:
After the first step of the SemontPLUS, the application of "vibrations" increased the angular displacement of single particles from 119.9 to 125.9 degrees and clumps from 106.7 to 122.8 degrees. Clumps traveled shorter distances than single particles. "Rapid decelerations" also increased the angular displacement from 119.9 to 123.4 degrees and from 106.7 to 111.7 degrees for singles and clumps, respectively. "Vibrations" and "rapid decelerations" applied on the in vitro model resulted in enhanced repositioning success rates to 60 and 73%, respectively.
Conclusions:
Adding "rapid decelerations" or "vibrations" to the SemontPLUS maneuver increased otolith particle displacement and improved the repositioning success rates in an in vitro model. However, the effect size of these additional modalities on angular displacement is small, and their use in clinics to improve repositioning in the SemontPLUS would have to be supported by further clinical trials.
Related Concept Videos
Power Expended by a Constant Force
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:

