Related Experiment Video
Updated: Jul 13, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
The role of renal dual-energy computed tomography in exploring the gouty kidney: the RENODECT study
Tristan Pascart1, Elie Dauphin1, Chio Yokose2
1Department of Rheumatology, Lille Catholic University, Saint-Philibert Hospital, ETHICS laboratory, Lille, EA, France.
Objective:
The objective of this study was to explore the ability of dual-energy computed tomography (DECT) to detect monosodium urate (MSU) crystal deposits in the kidneys and renal artery walls, and uric acid urolithiasis, in patients with gout and chronic kidney disease (CKD).
Methods:
Patients with gout and with stage 2-4 CKD were prospectively included in this cross-sectional study. Patients underwent renal, knee and feet DECT scans. Renal DECT scans were read for MSU-coded lesions in the kidneys, renal artery walls, and urinary tract using different post-processing settings. Characteristics of patients with and without DECT-positive lesions were compared, and the DECT parameters of these lesions were measured.
Results:
A total of 27/31 patients with had renal DECT scans and were included in the analysis (23/27 men, mean (standard deviation) 73 (9) years old, mean eGFR 45.3 mL/min/1.73 m2 (21.0), volumes of MSU in the knees and feet ranging from 0.11 to 475.0 cm3). None of the patients exhibited deposition of MSU crystals in the kidneys. One case of calyceal calculi and one case of ureterolithiasis were observed, wrongly coded as MSU in default post-processing settings for gout but identified as uric acid in the "kidney stone" settings. Five patients had MSU-coded plaques in the renal arteries, which had DECT parameters consistent with early calcified plaques rather than MSU, and had no association with volumes of peripheral MSU deposition.
Conclusion:
DECT is unable to detect genuine monosodium urate crystal deposits in kidneys and renal artery walls, and but can characterize chronic asymptomatic urolithiasis.
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation I: X-ray and CT
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

