Accuracy of Two-compartment Modeling of Gas Exchange with Ventilation-Perfusion Mismatch in Inhalational Anesthesia
1Department of Critical Care, Melbourne Medical School, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Melbourne, Victoria, Australia; Institute of Breathing and Sleep (IBAS), Heidelberg, Victoria, Australia; Department of Anaesthesia, Austin Health, Heidelberg, Victoria, Australia.
Background:
Multicompartment computer models of heterogeneity in alveolar ventilation-perfusion ratios V̇ A /Q̇ scatter) across the lung explain the significant alveolar-arterial partial pressure gradients and associated alveolar dead-space fractions (V da /V a ) seen in anesthetized patients for both carbon dioxide and for anesthetic gases of different blood solubilities. However, the accuracy of a simpler two-compartment model of V̇ A /Q̇ scatter to do this has not been tested or compared to calculations from the traditional Riley model with "ideal," unventilated (shunt) and unperfused (dead-space) compartments.
Methods:
Measurements of gas partial pressures in inspired and expired gas and arterial and mixed venous blood from 29 patients undergoing inhalational general anesthesia for cardiac surgery were used to compare the accuracy of two simple models of V̇ A /Q̇ scatter and lung gas exchange in predicting measured alveolar and arterial partial pressure differences and the associated alveolar dead-space calculations for the modern anesthetic gases isoflurane, sevoflurane, and desflurane. These models were the Riley model and a two-compartment model with reciprocal proportions of allocation of V̇ A and Q̇, with and without additional true shunt. A multicompartment "log-normal" model was also tested.
Results:
Mean (95% CI) of the measured alveolar dead-space fraction for the three anesthetic gases G combined (V da /V aG ) was 0.557 (0.523 to 0.592). Mean V da /V aG from the two-compartment model incorporating an additional true-shunt lung compartment (0.539 [0.498 to 0.580]) was similar to the measured value ( P = 0.347) and was 0.501 (0.457 to 0.546) without a true-shunt compartment. The log-normal model outputs were 0.491 (0.453 to 0.529). The Riley model outputs for V da /V aG severely underestimated this (0.327 [0.294 to 0.361]).
Conclusions:
Satisfactory prediction of the alveolar-arterial partial pressure gradients and alveolar dead space for the modern volatile anesthetic gases measured in vivo requires a model with more than one gas-exchanging lung compartment, which the traditional Riley model lacks. A simple "reciprocal" two-compartment model achieves this.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...