Related Experiment Video
Updated: May 30, 2025

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
An in vitro study of contrast agent optimization for MR hysterosalpingography
Jin Ding1, Huanzhi Ding2, Ximing Wang2
1Department of Obstetrics and Gynecology Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, PR China.
Abstract:
BackgroundGadolinium-iodine mixed contrast agents can significantly improve the visualization of the fallopian tubes in magnetic resonance hysterosalpingography (MR-HSG). However, the mixing ratio of gadolinium-iodine contrast agents has not yet been standardized.PurposeTo explore the optimal mixing ratio of gadolinium-iodine contrast agents suitable for MR-HSG.Material and MethodsA total of 16 mixing ratios of gadolinium and saline mixtures (Gd-NS), gadolinium and iopromide mixtures (Gd-I370), and gadolinium and iodixanol mixtures (Gd-I320) were formulated for an in vitro study. These mixed contrast agents were scanned on 1.5 T and 3.0 T using T1 contrast enhancement sequences. For qualitative assessment, contrast agent imaging quality was graded on a subjective 3-point scale (good, moderate, and poor). For the quantitative evaluation, differences in the signal intensity (SI) of the three contrast agents, as well as the SI variations between 1.5 T and 3.0 T, were compared.ResultsGd-I370 and Gd-I320 exhibited the highest SI and good image at a 1:300 ratio on 1.5 T and a 1:200 ratio on 3.0 T. The difference in the SI among the three contrast agents was not statistically significant at 1.5 T (P > 0.05). At 3.0 T, the comparison between the SIs of Gd-I370 and Gd-I320 was not statistically significant (P > 0.05). The SIs of contrast agents on 3.0 T were higher than those on 1.5 T (P < 0.05).ConclusionA gadolinium-iodine contrast agent with a 1:300 mixing ratio may be more suitable for 1.5 T MR-HSG, while a 1:200 mixing ratio may be more suitable for 3.0 T MR-HSG. Additionally, the contrast agent SI is higher on 3.0 T than on 1.5 T.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...