Background:
Titration of oxygen therapy to target safe oxygen saturation (SpO2) values is a vital part of care for preterm infants, but is difficult to achieve, particularly in settings in which oxygen, monitoring technology, and human resources are scarce. We aimed to evaluate the safety and efficacy of automated titration of oxygen therapy partnered with a low-cost continuous positive airway pressure (CPAP) device versus manual oxygen control in preterm infants requiring CPAP in a high-mortality, low-resource setting.
Methods:
In this open-label, randomised, crossover trial, preterm infants with a gestational age younger than 34 weeks (or a birthweight <2 kg if gestation was unknown) who were aged 12 h or older and required CPAP and oxygen were recruited at two hospitals in southwest Nigeria. Participants were randomly assigned (1:1) to one of two intervention sequences (ie, to commence the study on automated oxygen control or manual oxygen control) with block randomisation (blocks of 4 and 6) and stratification by health facility. The study statistician was masked to treatment group assignment, but the participants' parents or caregivers and clinical staff were not. Participants received automated or manual oxygen control for two 24-h periods in random sequence. Automated oxygen titration was done with a control algorithm with proven efficacy in high-resource settings. During periods of manual control, oxygen therapy was adjusted by clinicians. The primary outcome was the adjusted mean difference in the proportion of time participants spent in the SpO2 target range (ie, SpO2 91-95% when receiving oxygen or SpO2 91-100% when not receiving oxygen) between automated and manual oxygen control, analysed by intention to treat with weighted repeated measures mixed model linear regression. This trial is registered with ClinicalTrials.gov, NCT05508308, and is completed.
Findings:
Between Sept 13, 2022, and Sept 11, 2023, 72 infants were screened, and 49 (22 female, 27 male; median gestation 29 weeks [IQR 28-31]; median birthweight 1·2 kg [1·1-1·5]) were enrolled in the study and randomly assigned. A total of 80 study periods for 46 infants contributed data to the analysis of the primary outcome as three (6%) of the 49 participants had no oxygenation data from either study period. The mean proportion of time spent in the SpO2 target range was higher during automated control periods than during periods of manual control (adjusted mean 88·1% [95% CI 84·0-92·2] vs 30·1% [20·9-39·3]; adjusted mean difference 58·0% [95% CI 48·0-67·9]; p<0·0001). There were no device-related adverse patient outcomes and short-term safety outcomes favoured automated control.
Interpretation:
Automated titration of oxygen partnered with a low-cost CPAP device improved time spent in the safe SpO2 range compared with manual control. There is high potential for this technology to mitigate the risk of oxygen-mediated complications in preterm infants in low-resource settings.
Funding:
National Health and Medical Research Council Australia and University of Tasmania.
More Related Videos
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...