Direct rapid analysis of hazardous analytes in aerosol products using gas-flow-assisted electrostatic field-induced
Xiangyu Guo1, Yuhang Shang1, Hua Bai1
1Chinese Academy of Inspection and Quarantine, Beijing, 100176, China.
Abstract:
Safe, rapid, and sensitive analysis of hazardous chemical compounds in aerosol products significantly benefits both inspector and operator health and detection throughput. This study presents a novel approach for the direct mass spectrometry analysis of regulated chemical compounds in aerosol products, utilizing gas-flow-assisted transfer/nebulization and electrostatic field-induced spray ionization via a custom-made double-tee assembly. Without any pretreatment or solvent, samples are introduced into the assembly, which transfers the sample and generates microdroplets using high-pressure sheath gas. Target analyte ions are mixed with formic acid or derivatization reagent microdroplets in the cavity and then directed into an ion trap mass spectrometer through an electrostatic field for quantitative analysis. Key parameters of the double-tee assembly were systematically optimized using response surface methodology, achieving excellent analytical performance. Sample consumption was 20 μL, and the whole analytical procedure was completed within 1 min. The limits of detection and quantitation for target compounds were in the range of 10-25 μg/kg and 25-50 μg/kg, respectively. The proposed method exhibited good recoveries between 94.3 % and 101.3 %, with relative standard deviations from 2.4 % to 8.2 %. Moreover, this method has the potential to monitor chemical reaction intermediates and distinguish sample authenticity through multivariate statistical analysis. Overall, it is user-friendly for aerosol product analysis and prioritizes operator safety and health.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Overview