Related Experiment Video
Updated: May 29, 2025

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
Endoscopic Ultrasound-Guided Portosystemic Pressure Gradient Correlates With Clinical Parameters and Liver Histology
Jennifer M Kolb1, Marc Monachese2, Raymond A Rubin3
1Vatche and Tamar Manoukian Division of Digestive Diseases, David Geffen School of Medicine at UCLA, Los Angeles, California.
Background & Aims:
Endoscopic ultrasound-guided portosystemic pressure gradient measurement (EUS-PPG) is a novel technique to evaluate for portal hypertension (PH), a diagnosis that can prognosticate and guide therapy for patients. This study evaluated the safety and efficacy of EUS-PPG and correlation with clinical parameters and liver histology.
Methods:
We conducted a multicenter, retrospective study of patients undergoing EUS-PPG from January 2020 to December 2022 for suspected liver disease or PH. Linear regression was used to examine the relationship between EUS-PPG and clinical parameters of PH, and the chi-square test, Fisher's exact test, and Wilcoxon rank sum test described correlation with liver biopsy histology and noninvasive markers of fibrosis (Fibrosis-4, APRI [aspartate aminotransferase-to-platelet ratio index]). Logistic regression was performed to identify the strongest predictor of histologic cirrhosis.
Results:
Across 8 centers, 385 patients were enrolled and 373 had successful EUS-PPG (technical success 97%). Higher median PPGs were observed in patients with than without esophageal varices (11.6 mm Hg vs 4.1 mm Hg), portal hypertensive gastropathy (10.5 mm Hg vs 3.3 mm Hg), and thrombocytopenia (7.6 mm Hg vs 4.4 mm Hg) (P < .001). Individuals with PH and clinically significant PH (PPG ≥10) were 6.7 and 3.8 times more likely to have cirrhosis on histology, respectively. EUS-PPG was the best overall predictor of biopsy-proven cirrhosis (area under the curve 0.84) compared with Fibrosis-4 (0.72), and APRI (0.54). There were 2 minor adverse events related to PPG (postprocedural pain).
Conclusions:
EUS-PPG measurement was technically feasible and safe and demonstrated a strong correlation with clinical parameters of PH and liver histology. The strongest predictor of cirrhosis was EUS-PPG >5 mm Hg, which outperformed noninvasive markers of fibrosis.
More Related Videos
09:37Invasive Hemodynamic Characterization of the Portal-hypertensive Syndrome in Cirrhotic Rats
Published on: August 1, 2018
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Liver Histology
Hepatocytes perform a variety of essential functions. They secrete...