Related Experiment Video
Updated: May 29, 2025

Author Spotlight: Enhancing Multicolor Fluorescence Localization in Lung Carcinoma Sample
Published on: November 21, 2023
Tumor Cellularity Assessment Using Artificial Intelligence Trained on Immunohistochemistry-Restained Slides Improves
Arkadiusz Gertych1, Natalia Zurek2, Natalia Piaseczna3
1Faculty of Biomedical Engineering, Silesian University of Technology, Zabrze, Poland; Department of Pathology and Laboratory Medicine, Cedars-Sinai Medical Center, Los Angeles, California; Department of Surgery, Cedars-Sinai Medical Center, Los Angeles, California.
None:
Tumor cellularity (TC) in lung adenocarcinoma slides submitted for molecular testing is important in identifying actionable mutations, but lack of best practice guidelines results in high interobserver variability in TC assessments. An artificial intelligence (AI)-based pipeline developed to assess TC in hematoxylin and eosin (H&E) whole slide images (WSIs) and in tumor areas (TAs) within WSIs includes a new model (CaBeSt-Net) trained to mask cancer cells, benign epithelial cells, stroma in H&E WSIs using immunohistochemistry-restained slides, and a model to detect all cell nuclei. High masking accuracy (>91%) by CaBeSt-Net computed using 1024 H&E regions of interest and intraclass correlation coefficient >0.97 assessing TC assessments reliability by one pathologist and AI in 20 test regions of interest supported the pipeline's applicability to TC assessment in 50 study H&E WSIs. Using the pipeline, TCs assessed in TAs and WSIs were compared with those by three pathologists. Reliabilities of these ratings by the pathologists supported by the pipeline were good (intraclass correlation coefficient >0.82, P < 0.0001). The consistency of sample categorizations as inadequate or adequate (TC ≤ 20% cut point) for molecular testing among the pathologists assessing TCs without AI support was moderate in TAs (κ = 0.410, P < 0.0001) and slight in WSIs (κ = 0.132, nonsignificant). With AI support, the consistency was substantial in both WSIs (κ = 0.602, P < 0.0001) and TAs (κ = 0.704, P < 0.0001). By visualizing cancer and measuring TC in the sample, this novel AI-based pipeline assists pathologists in selecting samples for molecular testing.
More Related Videos
08:54Pathological Analysis of Lung Metastasis Following Lateral Tail-Vein Injection of Tumor Cells
Published on: May 20, 2020
06:47Expanding the Comprehension of the Tumor Microenvironment using Mass Spectrometry Imaging of Formalin-Fixed and Paraffin-Embedded Tissue Samples
Published on: June 29, 2022