Related Experiment Video
Updated: May 29, 2025

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
Published on: July 5, 2016
Characterization of material using dual-energy gamma-ray tomography: Determination of atomic number and density
Patrício Luiz de Andrade1, Enivaldo Santos Barbosa1, Daniel Milian Pérez1
1Departamento de Energia Nuclear, Universidade Federal de Pernambuco (UFPE), Cidade Universitária, Avenida Professor Luiz Freire 1000, Recife, PE, Brazil.
Abstract:
This study presents a new mathematical model for determining the atomic number and density of materials using dual-energy gamma-ray transmission tomography. The proposed method is based on an algebraic function that relates the atomic number to the attenuation ratio, offering an innovative approach for the precise characterization of materials. The methodology employed involved the theoretical development of the model, followed by tests using data from NIST XCOM and practical experiments with a gamma-ray transmission tomograph using americium-241 (59.5 keV) and cesium-137 (662 keV) sources. Two sets of materials were used: one group of 10 elements for determining the calibration curves and another with 4 elements (graphite, magnesium, aluminum, and iron) for validating the theoretical and experimental calibration curves. Unlike existing methods, which predominantly utilize polynomial or exponential relationships, the proposed model introduces a novel algebraic approach to enhance accuracy and computational efficiency. The performance of the new model was compared with approaches used by other authors. The analyses were conducted for elements with atomic numbers between 6 and 30, covering a significant range of materials of practical and scientific interest. The results demonstrated that the proposed model presented discrepancies of less than 3.5% for the atomic number and a maximum error of 10.04% for the density, with a trend of decreasing errors as the atomic number increased.
More Related Videos
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
X-ray Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Atomic Emission Spectroscopy: Overview
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...

