Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Comparing Peristaltic and Direct-Drive Contrast Injection Systems for Thoracic Computed Tomography (CT): Effects on
Charbel Saade1, Suzanne Saab1, Jana El-Sakakini1
1Medical Imaging Sciences, American University of Beirut Medical Center, Beirut, LBN.
Abstract:
Introduction To compare thoracic vasculature opacification between the direct-drive and the peristaltic drive contrast injection systems and the effect on quantitative and qualitative image quality during computed tomography. Method A retrospective chart review of 88 patients who underwent chest computed tomography (CT) following a direct-drive injector before 2016 (Group A) or a peristaltic injector after 2016 (Group B). Both protocols employed 80mL of iodinated contrast media volume. Quantitative measurements of the thoracic vascular opacification, contrast-to-noise ratio (CNR), effective radiation dose, and arterial venous contrast ratio (AVCR) for each vessel were computed and compared. The measured values of vascular opacification, CNR, and dose length product (DLP) were assessed utilizing paired t-test and Pearson's correlation. Receiver operating characteristic (ROC), visual grading characteristics (VGC), and Cohen's kappa methodology were measured. Results There was no significant difference in the mean opacification of the chest vasculature (p > 0.05). The CNR in Group B was significantly lower than in Group A (p < 0.05) except for the brachiocephalic artery, proximal descending aorta, and the right pulmonary artery. Arterial venous contrast ratio at all anatomic levels demonstrated no statistical significance between groups. There were no differences in ROC, VGC, or kappa values between groups. Conclusion When comparing two contrast media injection systems in chest CT, there was no qualitative difference in image quality or pathology detection. However, quantitatively, direct-drive injectors provided higher CNR. Direct-drive contrast injectors also provided a superior quantitative image quality of chest vasculature compared to peristaltic injectors.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...