Related Experiment Video
Updated: Jun 13, 2025

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Assessment of Corneal Biomechanics and Intraocular Pressure With Scleral Lenses of Different Diameters
Juan Queiruga-Piñeiro1, Irene Martínez-Alberquilla, Ignacio Rodríguez-Uña
1Instituto Universitario Fernández-Vega (J.Q.-P., I.R.-U., A.B., J.L.-S., L.F.-V.C., J.M.-L.), Fundación de Investigación Oftalmológica, University of Oviedo, Oviedo, Spain; Instituto de Investigación Sanitaria Del Principado de Asturias (ISPA) (J.Q.-P., I.R.-U., A.B., J.L.-S., L.F.-V.C., J.M.-L.), Oviedo, Spain; Optometry and Vision Department (I.M.-A.), Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain; and Departament of Surgery and Medical-Surgical Specialities (L.F.-V.C., J.M.-L.), University of Oviedo, Oviedo, Spain.
Purpose:
To evaluate the short-term influence of scleral lenses (SL) with different diameters on intraocular pressure (IOP) and corneal biomechanics. A secondary objective was to investigate the relationship between fluid reservoir (FR) thickness and IOP and biomechanical parameters.
Methods:
Thirty healthy subjects were randomly fitted with L1 (diameter of 15.80 mm) and L2 (diameter of 16.80 mm) on the right eye and worn for 2 hr. On IOP and corneal biomechanical parameters were measured with the CORVIS ST before and after SL removal. Fluid reservoir thickness at 0 and 2 hr of wear was measured using anterior segment optical coherence tomography.
Results:
Biomechanical parameters decreased after removal of L1 (-1.04±1.47 mm Hg) ( P <0.01) and L2 (-0.80±1.74 mm Hg) ( P =0.02). The biomechanical parameters A1T (-0.11±0.18 ms) ( P =0.01) and SP-A1 (-4.29±9.97 mm Hg/mm) ( P =0.02) decreased after L1 removal, whereas a decrease in highest concavity time (-0.21±0.50 m/s) ( P =0.03) and an increase in highest concavity radius (+0.17±0.43 mm) ( P =0.04) were observed after L2 removal. A significant, negative, and moderate correlation was found between highest concavity deformation amplitude and FR thickness with L1 (r=-0.42, P =0.02).
Conclusions:
The small changes in corneal biomechanical parameters and IOP values induced by short-term SL wear have no significant clinical impact and were not influenced by the diameter of the SL.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment

