Related Experiment Video
Updated: May 29, 2025

Evolution of Staircase Structures in Diffusive Convection
Published on: September 5, 2018
Research on coupling evacuation of escalator and staircase in fire scenario
Chunhua Zhang1,2, Xin Wu1,2, Hai Shen3
1College of Safety Science and Engineering, Liaoning Technical University, Fuxin, China.
Abstract:
In order to improve mall evacuation efficiency, Pyrosim software and Anylogic software are used to study the coupled evacuation of mall personnel using escalators and stairs in a fire scenario. The available safe evacuation time of each evacuation exit was explored by analyzing the smoke transport, temperature, CO concentration and visibility of each floor of the mall under different fire source locations when the fire shutter was lowered to 1.8m from the ground. Then, the evacuation model of mall personnel under fire scenario was built by using Anylogic to compare and analyze the evacuation time of mall personnel using escalators coupled with stairs and stairs only, and analyze the evacuation time of personnel using escalators coupled with stairs when the fire shutter at the escalator is down to 1.8m from the ground and when the fire shutter is not down. The study shows that when the fire source is located on the top floor of the mall, the smoke does not affect the evacuation of people on other floors during the simulation time. Under the fire scenario, the escalator-coupled staircase evacuation can shorten the maximum evacuation time by 23.37% compared with the staircase only. The fire shutter descends to 1.8m from the ground and the evacuation efficiency is 6.41% higher than when the fire shutter is not descended. This research contributes to the enhancement of mall safety and has practical implications for future emergency management strategies in public spaces.
Related Concept Videos
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Design Example: Designing Water Slide
Bernoulli's principle determines the water's velocity along the...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...

