Related Experiment Video
Updated: May 28, 2025

Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Development of a Bunching Ionizer for TOF Mass Spectrometers with Reduced Resources
Oya Kawashima1,2, Satoshi Kasahara2, Yoshifumi Saito1,2
1Institute of Space and Astronautical Science (ISAS), Japan Aerospace Exploration Agency (JAXA), 3-1-1 Yoshinodai, Sagamihara, Kanagawa 252-5210, Japan.
Abstract:
In some types of mass spectrometers, such as time-of-flight mass spectrometers (TOF-MSs), it is necessary to control pulsed beams of ions. This can be easily accomplished by applying a pulsed voltage to the pusher electrode while the ionizer is continuously flowing ions. This method is preferred for its simplicity, although the ion utilization efficiency is not optimized. Here we employed another pulse-control method with a higher ion utilization rate, which is to bunch ions and kick them out instead of letting them stream. The benefit of this method is that higher sensitivity can be achieved; since the start of new ions cannot be allowed during TOF separation, it is highly advantageous to bunch ions that would otherwise be unusable. In this study, we used analytical and numerical methods to design a new bunching ionizer with reduced resources, adopting the principle of the electrostatic ion beam trap. The test model experimentally demonstrated the bunching performance with respect to the sample gas density and ion bunching time using gas samples and electron impact ionization. We also conducted an experiment connecting the newly developed bunching ionizer with a miniature TOF-MS. As a result, the sensitivity was improved by an order of magnitude compared to the case using a nonbunching ionizer. Since the device is capable of bunching ions with low voltage and power consumption, it will be possible to find applications in portable mass spectrometers with reduced resources.
Related Concept Videos
Mass Analyzers: Common Types
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Spectrometers
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Analyzers: Overview
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...

