Related Experiment Video
Updated: May 2, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
In-vitro investigation of bone temperature changes in osteotomies performed with different brands of implant burs
Ömer Faruk Şarkbay1, Ahmet Mihmanli2, Hakan Cora3
1Istanbul Gelisim University-Vocational School of Health, Istanbul, Türkiye.
Abstract:
The aim of this study was to investigate in-vitro the temperature changes occurring in the bone during drilling with implant drills manufactured by different companies. Bone blocks obtained from fresh bovine ribs were used in the study. Bone blocks were drilled with drills manufactured by Ankylos, Astra Tech, Nobel Biocare, Bredent and Straumann implant brands at an ambient temperature of 30 ± 2° C under a constant pressure of 2 kg. Two K-type thermocouple sensors were placed on the bone blocks at 5th and 10th mm depths and the temperature changes were measured at a distance of 1 mm from the implant drill. In the study, working models were created under different conditions for implant socket preparation. In group 1, the first time drills were used at 150 rpm without irrigation, in group 2, the first time drills were used at 1200 rpm with 40 ml/min irrigation, in group 3, the 30th time drills were used at 150 rpm without irrigation, and in group 4, the 30th time drills were used at 1200 rpm with 40 ml/min irrigation. All osteotomy procedures were performed with 3.5 ± 0.3 mm diameter burs for a period of 8 s and the temperature values obtained at equal time intervals were recorded. Repeated Measures and Kruskall Wallis-H tests were used for statistical analysis of the data. No significant difference was observed between the implant drills and the temperature changes in the bone during drilling (p < 0.05). None of the groups reached critical temperature values (47° C+) throughout the study. At the 5th and 10th mm depths, the temperature changes in the sensors used were close to each other. It was also calculated that although the average temperatures were close to each other in the non-irrigated and irrigated systems, the difference values obtained by subtracting the initial temperature were significantly higher in the non-irrigated systems. The results showed that implant drills did not cause significant temperature increases in bone blocks depending on the difference in manufacturers (Ankylos, Astra Tech, Nobel Biocare, Bredent, Straumann) and the number of uses. It was also concluded that irrigated and non-irrigated systems are safe as long as they are used under the recommended conditions.
More Related Videos
Related Concept Videos
Bone Remodeling
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Blood and Nerve Supply to the Bones
Nutrient Artery
The nutrient artery is the main blood vessel that enters the diaphysis via the nutrient foramen. While most long bones have only one nutrient foramen, large bones, such as the femur, may have two. This...