Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo
Published on: September 22, 2017
Optical Coherence Tomography Image Enhancement and Layer Detection Using Cycle-GAN
Ye Eun Kim1, Eun Ji Lee2, Jung Suk Yoon2
1Department of Statistics and Data Science, Yonsei University, Seoul 03722, Republic of Korea.
Abstract:
Background/Objectives: Variations in image clarity across different OCT devices, along with the inconsistent delineation of RNFL boundaries, pose a challenge to achieving consistent diagnoses for glaucoma. Recently, deep learning methods such as GANs for image transformation have been gaining attention. This paper introduces deep learning methods to transform low-clarity images from one OCT device into high-clarity images from another, concurrently estimating the retinal nerve fiber layer (RNFL) segmentation lines in the enhanced images. Methods: We applied two deep learning methods, pix2pix and cycle-GAN, and provided a comparison of their performance by evaluating the similarity between the generated and actual images, as well as comparing the generated RNFL boundary delineation with the actual boundaries. Results: The image conversion performance was compared based on two criteria: Fréchet Inception Distance (FID) and curve dissimilarity. In the comparison of FID values, the cycle-GAN method showed significantly lower values than the pix2pix method (p-value < 0.001). In terms of curve similarity, the cycle-GAN method also demonstrated higher similarity to the actual curves compared to both manually annotated curves and the pix2pix method (p-value < 0.001). Conclusions: We demonstrated that the cycle-GAN method produces more consistent and precise outcomes in the converted images compared to the pix2pix method. The resulting segmented lines showed a high degree of similarity to those manually annotated by clinical experts in high-clarity images, surpassing the boundary accuracy observed in the original low-clarity scans.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...