Accurate Cardiac Duration Detection for Remote Blood Pressure Estimation Using mm-Wave Doppler Radar
Shengze Wang1, Mondher Bouazizi2, Siyuan Yang2
1Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan.
Abstract:
This study introduces a radar-based model for estimating blood pressure (BP) in a touch-free manner. The model accurately detects cardiac activity, allowing for contactless and continuous BP monitoring. Cardiac motions are considered crucial components for estimating blood pressure. Unfortunately, because these movements are extremely subtle and can be readily obscured by breathing and background noise, accurately detecting these motions with a radar system remains challenging. Our approach to radar-based blood pressure monitoring in this research primarily focuses on cardiac feature extraction. Initially, an integrated-spectrum waveform is implemented. The method is derived from the short-time Fourier transform (STFT) and has the ability to capture and maintain minute cardiac activities. The integrated spectrum concentrates on energy changes brought about by short and high-frequency vibrations, in contrast to the pulse-wave signals used in previous works. Hence, the interference caused by respiration, random noise, and heart contractile activity can be effectively eliminated. Additionally, we present two approaches for estimating cardiac characteristics. These methods involve the application of a hidden semi-Markov model (HSMM) and a U-net model to extract features from the integrated spectrum. In our approach, the accuracy of extracted cardiac features is highlighted by the notable decreases in the root mean square error (RMSE) for the estimated interbeat intervals (IBIs), systolic time, and diastolic time, which were reduced by 87.5%, 88.7%, and 73.1%. We reached a comparable prediction accuracy even while our subject was breathing normally, despite previous studies requiring the subject to hold their breath. The diastolic BP (DBP) error of our model is 3.98±5.81 mmHg (mean absolute difference ± standard deviation), and the systolic BP (SBP) error is 6.52±7.51 mmHg.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Special considerations while measuring pulse
Doppler Effect - II