Heart Rate Estimation Considering Reconstructed Signal Features Based on Variational Mode Decomposition via
Sara Nakatani1, Mondher Bouazizi2, Tomoaki Ohtsuki2
1Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan.
This study introduces a novel heart rate estimation method using Multiple-Input Multiple-Output Frequency Modulated Continuous Wave (MIMO FMCW) radar and Variational Mode Decomposition (VMD). The technique accurately isolates heart rate signals, even with multiple subjects, enhancing privacy and non-contact monitoring.
Area of Science:
- Biomedical Engineering
- Signal Processing
- Radar Technology
Background:
- Accurate heart rate estimation is crucial for non-invasive health monitoring.
- Existing radar-based methods face challenges in separating heartbeat signals from respiration and motion artifacts.
- Privacy concerns and the need for through-clothing measurement highlight the demand for advanced techniques.
Purpose of the Study:
- To develop a novel heart rate estimation method using MIMO FMCW radar and VMD.
- To improve the accuracy and robustness of radar-based heart rate monitoring.
- To enable reliable heart rate estimation in scenarios with multiple subjects.
Main Methods:
- Utilizing Multiple-Input Multiple-Output (MIMO) Frequency Modulated Continuous Wave (FMCW) radar for signal acquisition.
- Applying Variational Mode Decomposition (VMD) to decompose radar signals into Intrinsic Mode Functions (IMFs).
- Extracting the heartbeat-specific IMF based on its center frequency and reconstructing the heart rate signal.
Main Results:
- The proposed VMD-based MIMO FMCW radar method achieved a Mean Absolute Error (MAE) of 2.54 BPM for a single subject.
- Demonstrated accurate simultaneous heart rate estimation for two subjects with an MAE of 2.28 BPM.
- Outperformed traditional Doppler radar methods, showing significantly lower error rates.
Conclusions:
- The VMD-based MIMO FMCW radar approach offers a robust and accurate solution for non-contact heart rate estimation.
- The method effectively isolates heartbeat signals, overcoming limitations of conventional techniques.
- This technology holds promise for enhanced privacy-preserving remote health monitoring.