Related Experiment Video
Updated: Oct 3, 2026

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Research on active noise control for villa elevators based on transmission path analysis and complex spectrum
XiaoXin Wang1, Qing Zhang1, LuHui Yang1
1School of Mechanical and Electrical Engineering, Shandong Jianzhu University, Jinan 250101, Shandong Province, People's Republic of China.
Abstract:
Villa elevator noise is predominantly concentrated in the 20-500 Hz frequency range, with a reverberation time of 0.2 s, which is far shorter than the 0.4 s of conventional elevators. This makes it challenging for adaptive filters to guarantee effective noise reduction performance. A novel deep learning-based active noise cancellation method is proposed based on Dominant Transmission Path and Complex-spectrum Network (DTPC-Net). First, a transmission path model was established, and the primary noise source and its dominant propagation direction were identified based on coherence analysis and energy distribution. Subsequently, a one-dimensional modeling strategy oriented toward the dominant propagation direction is proposed to address the high computational complexity of three-dimensional modeling. Furthermore, a convolutional recurrent network was designed to estimate the complex spectrum of noise signal. A hierarchical long short-term memory module and a Squeeze-and-Excitation attention module were incorporated to capture dynamically varying noise features. In addition, a predictive compensation mechanism based on blank frame padding was proposed to train the neural network and mitigate system delay. Finally, noise was reduced by 10.29 dB and 8.76 dB when the villa elevator operates at 0.4 m/s and 1 m/s, respectively. And the corresponding A-weighted reductions were 7.62 dBA and 7.54 dBA.
Related Concept Videos
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Effects of Air-entrainment in Concrete
Vibrating Concrete
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal and...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the system's...
Control Systems
At the heart...