Estimation of the Measurement Accuracy of Wireless Passive Resonance Sensors

Leonhard M Reindl1, Taimur Aftab1, Thomas Schaechtle1

  • 1Laboratory for Electrical Instrumentation and Embedded Systems, Faculty of Engineering, University of Freiburg, 79110 Freiburg, Germany.

PubMed

Related Concept Videos

Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
181
Characteristics of Series Resonant Circuit01:24

Characteristics of Series Resonant Circuit

Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
217
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
25
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
59
Potentiometer01:30

Potentiometer

Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
524
Design Example: Underdamped Parallel RLC Circuit01:17

Design Example: Underdamped Parallel RLC Circuit

Consider designing an oscillator circuit, a crucial component in various electronic devices and systems. The objective is to create an oscillator circuit with specific characteristics: a damped natural frequency of 4 kHz and a damping factor of 4 radians per second. To accomplish this, a parallel RLC circuit is employed, known for its ability to sustain oscillations at a resonant frequency. In this case, the damping factor is pivotal in achieving the desired performance.
Starting with a fixed...
253