Related Experiment Video
Updated: May 27, 2025

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Produced radioactive isotopes, ambient dose equivalent in TrueBeam room with flattening filter (FF) and Flattening
Soai Dang Quoc1, Toshioh Fujibuchi2, Hiroyuki Arakawa2
1Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan; Department of Medical Physics, Hanoi Oncology Hospital, 42A Thanh Nhan Street, Hai Ba Trung District, Hanoi, Viet Nam.
Background:
High-energy linear accelerators used in radiotherapy produce unexpected neutrons that can activate materials in the treatment room.
Materials And Methods:
The research group used PHITS code to simulate TrueBeam Linac head with 10 MV photons. Then, PHITS codes connected Dchain code to calculate the variation of the induced radioactivity, the ambient dose equivalent during TrueBeam radiation 4 Gy with dose rate 400 MU (Monitor Unit)/minute in FF mode, 24 Gy with dose rate 2400 MU/minute in FFF mode, and cooling time (14 min).
Results:
One minute of beam-on TrueBeam with 10 MV photon energy produced six mainly produced nuclides (183 mW, 24mNa, 185 mW, 28Al, 24mNa, and 187W). FFF mode had more activity of the produced isotopes than those in FF mode (1.60 × 1014 Bq compared with 1.57 × 1014 Bq-corresponding to ∼1.71% higher). The differences in the activity of isotopes and ambient dose between FF and FFF mode were mostly less than a few percent; however, considering that the MU per beam current is six times higher in the FFF mode than in the FF mode, the induced activities per MU can be reduced by roughly six times when using the FFF mode instead of the FF mode.
Conclusion:
The isotope activities of the produced isotopes in the FF and FFF modes are essentially equivalent when normalized per beam current.
More Related Videos
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...