Related Experiment Video
Updated: May 27, 2025

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Sub-1-min relaxation-enhanced non-contrast non-triggered cervical MRA using compressed SENSE with deep learning
Jan Paul Janssen1, Kenan Kaya2, Robert Terzis2
1Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany. jan.janssen@uk-koeln.de.
Background:
We evaluated the acceleration of a three-dimensional isotropic flow-independent magnetic resonance angiography (MRA) (relaxation-enhanced angiography without contrast and triggering, REACT) of neck arteries using compressed SENSE (CS) combined with deep learning (adaptive intelligence, AI)-based reconstruction (CS-AI).
Methods:
Thirty-four volunteers received 3-T REACT MRA, acquired threefold: (i) CS acceleration factor 7 (CS7), scan time 1:20 min:s; (ii) CS acceleration factor 10 (CS10), scan time 0:55 min:s; and (iii) CS-AI acceleration factor 10 (CS10-AI), scan time 0:55 min:s. Two radiologists rated the image quality of seven arterial segments and overall image noise. Additionally, a pairwise forced-choice comparison was conducted. Apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR) were measured, and image sharpness was assessed using the edge-rise distance (ERD). Multiple t-tests and nonparametric tests with Bonferroni correction were performed for comparison to CS7 as the reference standard.
Results:
Compared to CS7, CS10 showed lower image quality (p < 0.001) while CS10-AI obtained higher scores (p = 0.010). Image noise was similar between CS7 and CS10 (p = 0.138) while CS10-AI yielded a lower noise (p = 0.008). Forced choice revealed preferences for CS7 over CS10 (p < 0.001), but no preference between CS7 and CS10-AI (p > 0.999). Compared to CS7, aSNR and aCNR were lower in CS10 (p < 0.001) and the ERD was longer (p = 0.004), while CS10-AI provided better aSNR and aCNR (p = 0.001) and showed no difference in ERD (p = 0.776).
Conclusion:
Sub-1-min CS-AI cervical REACT MRA was acquired without compromising image quality.
Relevance Statement:
The implementation of a fast and reliable non-contrast MRA has the potential to reduce costs and time while increasing patient comfort and safety. Clinical studies evaluating the diagnostic performance for stenosis or dissection are needed.
Trial Registration:
DRKS00030210 (German Clinical Trials Register; https://drks.de/ ) KEY POINTS: Deep learning reconstruction enables sub-1-min non-contrast-enhanced MRA of extracranial arteries. Acceleration without deep learning reconstruction causes inferior image quality. Acceleration with deep learning reconstruction exceeds, in part, the clinical standard.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...