Related Experiment Video
Updated: May 26, 2025

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Bioprosthetic valve thrombosis developed shortly after aortic valve replacement
Akito Kuwano1, Masaru Yoshikai1, Hisashi Sato1
1Department of Cardiovascular Surgery, Shin-Koga Hospital, Kurume City, Japan.
Abstract:
We present the case of an 83-year-old woman who presented with acute bioprosthetic valve thrombosis following surgical aortic valve replacement. On postoperative day 7, transthoracic echocardiography revealed reduced leaflet mobility in an implanted bioprosthetic valve, and contrast-enhanced computed tomography showed hypoattenuated leaflet thickening, leading to the diagnosis of prosthetic valve thrombosis. This case demonstrates that bioprosthetic valve thrombosis can occur even in the acute phase following surgical aortic valve replacement, highlighting the importance of early diagnosis and intervention. Close monitoring of leaflet mobility and thickening via transthoracic echocardiography is essential, with contrast-enhanced computed tomography serving as a valuable complementary tool.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017