Related Experiment Video
Updated: May 26, 2025

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
Visit-to-visit blood pressure variability and clinical outcomes in peritoneal dialysis - based on machine learning
Yan Lin1,2, Chunyan Yi1, Peiyi Cao1
1Department of Nephrology, The First Affiliated Hospital of Sun Yat-sen University and Key Laboratory of Nephrology, National Health Commission and Guangdong Province, Guangzhou, China.
None:
This study aims to investigate the association between visit-to-visit blood pressure variability (VVV) in early stage of continuous ambulatory peritoneal dialysis (CAPD) and long-term clinical outcomes, utilizing machine learning algorithms. Patients who initiated CAPD therapy between January 1, 2006, and December 31, 2009 were enrolled. VVV parameters were collected during the first six months of CAPD therapy. Patient follow-up extended to December 31, 2021, for up to 15.8 years. The primary outcome was the occurrence of a three-point major adverse cardiovascular event (MACE). Four machine learning algorithms and competing risk regression analysis were applied to construct predictive models. A total of 666 participants were included in the analysis with a mean age of 47.9 years. One of the six VVV parameters, standard deviation of diastolic blood pressure (SDDBP), was finally enrolled into the MACE predicting model and mortality predicting model. In the MACE predicting model, higher SDDBP was associated with 99% higher MACE risk. The association between SDDBP and MACE risk was attenuated by better residual renal function (p for interaction <0.001). In the mortality predicting model, higher SDDBP was associated with 46% higher mortality risk. This cohort study discerned that high SDDBP in early stage of CAPD indicated increased long-term MACE and mortality risks.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Factors affecting Blood pressure
Physiological Factors:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...