Related Experiment Video
Updated: May 26, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Phonoangiographic Diagnosis of Stenosed Arteries: A Computational Fluid Flexible-Structure Acoustic Interaction Study
Sumant R Morab1, Janani S Murallidharan1, Atul Sharma1
1Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai, India.
Abstract:
The present article is on pulsatile hemodynamics-induced sound-based diagnosis of stenosis in compliant arteries of three types: Coronary, carotid, and femoral. Considering axisymmetric stenosis in straight arteries along with clinically observed dimensions of the arteries and enveloping tissue, the present numerical study considers blood as a Newtonian fluid and both artery and tissue as isotropic and geometrically nonlinear (materialistically linear) solid. For the physiological fluid flexible-structure acoustic interaction (FfSAI) study, an in-house multiphysics solver is used for a parametric study-using various stenosis level (60%, 70%, and 80%) and stenosis length (2D and 4D); for each of the arteries. With increasing , an increase in acoustic acceleration's FFT spectrum-based cut-off frequency is found-indicating possibility of quantitative phonoangiographic diagnosis. The variation of this frequency with follows similar trend as that of frequency calculated by pressure fluctuation's FFT spectrum, thus correlating the hemodynamics as the cause for generation of the sound/bruits. Also, a flow-visualization-based frequency, which is calculated using vortex length and velocity during vortex dissipation stage, matches reasonably (≤ 15% difference) with the cut-off frequency of pressure fluctuation. For the first time in the literature, our sound velocity level-based study shows over-prediction of stenosis by neglecting flow-induced tissue deformations. This implies the importance of modeling structural flexibility, along with flow and acoustics while developing a computational Point-of-Care diagnostic tool. Finally, using analytical method for acoustics, a computationally efficient semi-analytical FfSAI approach is proposed. The present work is significant since an accurate and computationally efficient framework and flow-physics-based analysis are presented for phonoangiographic diagnosis of stenosed arteries of three types.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023