miRNA Library Preparation Optimisation for Low-Concentration and Low-Volume Paediatric Plasma Samples
Oenone Rodgers1, Chris Watson1, Thomas Waterfield1
1Wellcome-Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast BT9 7BL, UK.
Abstract:
Background: Analysing circulating miRNAs in paediatric plasma is challenging due to typically low sample volumes. The QIAseq miRNA UDI Library Kit (Qiagen, Hilden, Germany) was selected as it has a proven track record with a specific protocol for plasma and serum. The protocol, however, required optimisation for use with low-volume paediatric plasma samples before generating acceptable yields in our cohort. Methods: The miRNeasy Serum/Plasma kit (Qiagen) and the MagMAX miRVana Total Isolation kit (ThermoFisher Scientific, Waltham, MA, USA) were assessed following the manufacturer's instructions with 100 µL and 200 µL of paediatric plasma. Libraries were prepared using the QIAseq miRNA UDI Library Kit (Qiagen). Optimisations were made for the QIAseq miRNA UDI Library Kit (Qiagen) using total RNA extracted with the miRNeasy Serum/Plasma kit (Qiagen) from 100 µL of plasma. Results: Prior to optimisation, both RNA extraction kits underperformed with the QIAseq miRNA UDI Library kit, producing low miRNA library yields ranging between 0 and 1.42 ng/µL. Plasma input volumes of 100 µL and 200 µL demonstrated no significant differences. Adjusting the QIAseq protocol for low RNA concentrations improved miRNA library yields, an average of 5.6 ng/µL and a maximum of 24.3 ng/µL across 92 samples. The optimised protocol showed no age or gender biases with the QIAseq kit. Conclusions: Failure rates in miRNA library preparations are rarely reported, making it hard to gauge whether the 8.7% failure rate observed here is typical. However, given the challenges of using low-concentration, low-volume paediatric plasma, this represents a significant improvement over previous attempts, supporting further research in the field.
More Related Videos
13:24Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
Published on: April 11, 2016
08:12Detection of a Circulating MicroRNA Custom Panel in Patients with Metastatic Colorectal Cancer
Published on: March 14, 2019