Related Experiment Video
Updated: May 26, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Novel paper sensor with modified aptamer for accurate detection of clinical cardiac troponin I
Qing Xie1,2, Danfeng Wu1, Qinran Chen3
1Guangdong Provincial Key Laboratory of Construction and Detection in Tissue Engineering, Department of Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangdong 510515, Guangzhou, China. qqiuxzh@163.com.
Abstract:
Accurate and rapid detection of Cardiac Troponin I (CTnI) is essential for the early diagnosis and timely management of myocardial infarction (MI). However, conventional detection methods relying on antigen-antibody interactions often face challenges such as high costs and lengthy procedures. Novel detection methods based on antigen-aptamer interactions offer a potentially superior alternative. Nevertheless, the performance of antigen-aptamer sensors is typically compromised by the unstable structure of aptamers, resulting in limited sensitivity and inconsistent specificity in CTnI detection. To address these issues, we have developed an innovative aptamer structure to construct a paper-based sensor comprising a paper electrode and a CTnI aptamer detection module. The paper electrode employs PEDOT:PSS to uniformly distribute single-walled carbon nanotubes (SWCNTs) at high concentrations on filter paper. The detection module utilizes modified CTnI aptamers with a continuous (AT)5 sequence in the anchor domain to enhance stable immobilization on SWCNTs without chemical reactions. We discovered that incorporating appropriate 18-atom hexa-ethylene glycol spacers (Sp18) between the protein-capture and anchor domains of the aptamers can improve the sensitivity of the current response for CTnI detection. Through the optimization of annealing temperature and duration, the paper sensor Aps3-CTnI-PS@CP, which integrates (AT)5 and three Sp18 into the aptamer, demonstrated enhanced sensitivity and specificity for CTnI detection. When applied to clinical samples, Aps3-CTnI-PS@CP exhibited a favorable receiver operating characteristic (ROC) curve, with an area under the curve (AUC) of 0.982, a sensitivity of 0.917, and a specificity of 0.945 for CTnI detection. This performance correlates strongly with traditional chemiluminescence immunoassay (CLIA) assays used in clinical settings. The straightforward fabrication process and minimal batch-to-batch variability make Aps3-CTnI-PS@CP a promising candidate for clinical aptamer-based CTnI detection.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
08:58Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...